AX34209a_e.doc / Mrz-16
Page 33 / 38
9.
Technical Appendix
9.1.
Parameter Lists
9.1.1.
General
Function
Text
Min. value
Max. value
Default
Ser. Code
Operating Mode
mode
0
5
0
0
Brightness of Display
briGht
0
4
0
1
Display Update Time
UPdAtE
50
5999
300
28
Keypad Locking
CodE
0
2
0
20
Key Command
Cmd
0
3
0
D3
Range Input A
inPut A
0
2
1
6
Start Input A
StArt A
-99999
99999
0
7
End Input A
End A
-99999
99999
1000
8
Dec. Point Input A
dPoi A
0
5
1
10
Average Input A
Filt A
0
4
1
9
Offset Input A
OFFS A
-99999
99999
0
D4
Range Input B
inPut B
0
2
1
11
Start Input B
StArt B
-99999
99999
0
12
End Input B
End B
-99999
99999
1000
13
Dec. Point Input B
dPoi B
0
5
0
15
Average Input B
Filt B
0
4
0
14
Offset Input B
OFFS B
-99999
99999
0
D5
Proportional Factor
M FAc
-10000
10000
1000
3
Reciprocal Factor
D FAc
1
99999
1000
4
Additive Constant
P FAc
-99999
99999
0
5
Dec. Point
dPoint
0
5
0
2
9.1.2.
Presets / Relays
Function
Text
Min. value
Max. value
Default
Ser. Code
Preselection Value 1
PrES1
-99999
99999
10000
16
Preselection Value 2
PrES2
-99999
99999
5000
17
Source 1
Src 1
0
2
0
D6
Preselection Mode 1
CHAr1
0
3
0
18
Source 2
Src 2
0
2
0
D7
Preselection Mode 2
CHAr2
0
5
0
19
Hysteresis 1
HYSt1
0
99999
0
21
Hysteresis 2
HYSt2
0
99999
0
22