19
4.9
CHECK ON THE ADJUSTMENT OF THE LIMIT SWITCH
•
Press the button from the transmitter to
open the gate. The LED of every end-stop
unit will remain on until the wings are fully
open.
•
Press the button again from the transmit-
ter. The gate will begin to perform the clo-
sure and deceleration phases with the LED
off.
Red LED on
•
When closure is complete, check that the
red LED comes
on;
if the gate reverses its
movement, repeat adjustment of the cam
when closing, as described on page 8.
Red LED off
Closure phase
Deceleration phase
Red LED on
•
Close the electric panel with the screws
supplied.
Closure limit switch
•
Tighten the end-stop unit’s dome.