FUNCTION SELECTIONS
1 ON
Automatic closure;
the automatic
closure timer comes on at the end of the
opening movement and depends on the
intervention of possible safety accessories.
The waiting time that precedes closure is
adjustable (page 18).
This function is deactivated however after
a “stop” intervention or in the event of a
power failure;
Select the functions by setting the dip
switches to ON or OFF with a screwdriver,
as indicated in the figure.
By default, dip switches 7 and 8 are set to
“ON”.
2 ON - 3 OFF
Command type “Open-stop-
close-stop” with pushbutton (G-Ps) and
transmitter;
2 OFF - 3OFF
Command type “Open-close”
with pushbutton (G-Ps) and transmitter;
3 ON
Command type “Open only” with
transmitter;
4 ON
Pre-flashing in opening and closing;
after an opening or closing command, the
flashing lamp connected to 20 K1, flashes
for 5 seconds before the manoeuvre be-
gins.
5 ON
Obstacle detection with motor at limit
switch;
with motor off(door closed, open or
after a total-stop command), stops all move-
ment if the safety devices detect an obsta-
cle;
12
6
3
9
1
2
4
5
7
8
10
11
0"