[email protected] www.motorvac.com
12
Diesel Service
First Time Operation
The unit is tested at the factory with special test fluids then completely drained. These test fluids are
compatible with diesel engine systems. Because the unit is dry during shipping, it will be necessary to prime
the machine before it is put into service.
1. Remove the filter from below the diesel tank and fill it completely with diesel fuel and replace it on
the unit.
2. Connect the red battery clip to the positive (+) battery terminal and connect the black battery clip to a
solid chassis ground.
3. Pour 3 bottles of MV3D detergent into the diesel tank on the back right of the machine. See pg 13, for
alternate filling procedure.
4. Connect the DIESEL SIDE output (red) hose and the return (black) hose to each other using a matched
pair of adapters. This will allow the fuel to circulate and fill the system with solution.
5. Switch the ON/OFF switch to the ON position. NOTE: Alarm will sound continually until pump starts.
6. Press and hold the START switch for 3 minutes to circulate fluid through the machine.
7. Switch ON/OFF to OFF position to silence alarm.
8. Disconnect battery connections if unit is not to put into immediate use.