![Motortech MIC6 Скачать руководство пользователя страница 6](http://html1.mh-extra.com/html/motortech/mic6/mic6_quick-start-manual_1839338006.webp)
Status-Bits EN
P920380 - MIC6
Revision: 33493
General Status 2
these data were incomplete or invalid when the
configuration state was left. The warning is not set if no
coil data have been received.
If the configuration state is left after receiving complete
and valid coil data have been received, the warning is
reset.
4
Warning: Configuration Invalid
i
The warning is set if the configuration is invalid when the
configuration state is left. Otherwise the warning is reset.
5
Warning: Pickup Configuration
Invalid
i
The warning is set if a configuration with invalid pickup
settings has been transferred.
The warning is automatically reset after a valid pickup
configuration has been transferred.
6
Warning: Configuration Data CRC
Failure
i
The configuration stored in non-volatile memory could not
have been read because a CRC check failed.
The warning is reset after a new valid configuration is
stored.
7
Analog Current Input Failure
i
The analog current input signal fails.
8
Analog Voltage Input Failure
i
The analog voltage input signal fails.
9
Auxiliary Analog Input Supply
Voltage Failure
i
The measured value of the auxiliary analog input supply
voltage deviates from the set value.
10
Auxiliary Pickup Supply Voltage 1
Failure
i
The measured value of the auxiliary pickup supply
voltage 1 deviates from the set value.
11
Global Timing Limited
i
The global timing point is currently limited by the timing
limits.
12
Cylinder Individual Timing Limited
i
The cylinder individual timing offset of at least one output
exceeds the limits of the current schedule.
13
Auxiliary Pickup Supply Voltage 2
Failure
i
The measured value of the auxiliary pickup supply
voltage 2 deviates from the set value.
14..
20
reserved (for future use)
-
-
21
Pickup Redundancy Enabled
i
Pickup redundancy is enabled in the configuration.
22
Pickup Redundancy Available
i
More than one pickup set is synchronized and a failing
pickup set does not necessarily lead to an error.
23..
24
reserved (for future use)
-
-
25
Pickup Set 1: Synchronization
i
Pickup signals on pickup set 1 are available and are
being checked.
26
Pickup Set 1: Operation
i
Pickup signals on pickup set 1 are valid and the pickup
set is synchronized.
27..
28
reserved (for future use)
-
-
29
Pickup Set 2: Synchronization
i
Pickup signals on pickup set 2 are available and are
being checked.
30
Pickup Set 2: Operation
i
Pickup signals on pickup set 2 are valid and the pickup
set is synchronized.
31.. reserved (for future use)
-
-
6 / 8