background image

WS5100 Series Switch Installation Guide

8-2

(ii) reverse engineer, disassemble, decompile or otherwise attempt to discover the 
source code or structure, sequence and organization of the Software; or (iii) rent, lease, 
or use the Software for timesharing or service bureau purposes, or otherwise use the 
Software for any commercial purpose/on behalf of any third party. Licensee shall 
maintain and not remove or obscure any proprietary notices on the Software, and shall 
reproduce such notices exactly on all permitted copies of the Software. All title, 
ownership rights, and intellectual property rights in and to the Software, and any 
copies or portions thereof, shall remain in Licensor and its suppliers or licensors. 
Licensee understands that Licensor may modify or discontinue offering the Software 
at any time. The Software is protected by the copyright laws of the United States and 
international copyright treaties. The Software is licensed, not sold. This Agreement 
does not give Licensee any rights not expressly granted herein.

3. INTELLECTUAL PROPERTY; CONTENT. All title and intellectual property rights in and to 

the Software (including but not limited to any images, photographs, animations, video, 
audio, music, text and "applets" incorporated into the Software), and any copies you 
are permitted to make herein are owned by Licensor or its suppliers. All title and 
intellectual property rights in and to the content which may be accessed through use 
of the Software is the property of the respective content owner and may be protected 
by applicable copyright or other intellectual property laws and treaties. This EULA 
grants you no rights to use such content. As a condition to Licensee's use of the 
Software, Licensee represents, warrants and covenants that Licensee will not use the 
Software: (i) to infringe the intellectual property rights or proprietary rights, or rights 
of publicity or privacy, of any third party; (ii) to violate any applicable law, statute, 
ordinance or regulation; (iii) to disseminate information or materials in any form or 
format ("Content") that are harmful, threatening, abusive, harassing, tortuous, 
defamatory, vulgar, obscene, libelous, or otherwise objectionable; or (iv) to 
disseminate any software viruses or any other computer code, files or programs that 
may interrupt, destroy or limit the functionality of any computer software or hardware 
or telecommunications equipment. Licensee, not Licensor, remains solely responsible 
for all Content that Licensee uploads, posts, e-mails, transmits, or otherwise 
disseminates using, or in connection with, the Software.

4. FEES; SUPPORT AND UPGRADES. Licensor may, at Licensor's sole option, provide 

support services related to the Software ("Support Services"). Nothing in this 
Agreement grants Licensee any right to receive any Support Services. Use of any 
Support Services provided is governed by the Licensor policies and programs described 
in the user manual, in "online" documentation, and/or in other Licensor-provided 
materials or support agreements. Any supplemental software code provided to you as 

Содержание WS5100 Series

Страница 1: ...WS5100 Series Switch Installation Guide ...

Страница 2: ...rights reserved MOTOROLA and the Stylized M Logo are registered in the US Patent Trademark Office Symbol is a registered trademark of Motorola Inc All other product or service names are the property of their respective owners ...

Страница 3: ...pecifications 2 1 2 2 Power Cord Specifications 2 1 2 2 1 Power Protection 2 2 2 3 Cable Requirements 2 2 2 4 LED Codes 2 2 2 4 1 Start Up 2 2 2 4 2 Primary 2 3 2 4 3 Standby 2 3 2 4 4 Error Codes 2 3 Chapter 3 Hardware Setup 3 1 Installing the WS5100 3 1 3 2 Adding the WS5100 to the Network 3 2 3 3 Supplying Power to the WS5100 3 2 3 4 Verifying the Installation 3 3 ...

Страница 4: ...Information 4 2 4 3 Preliminary Switch Configuration 4 3 4 3 1 Web UI Requirements 4 3 4 3 2 Launching the WS5100 Series Switch Web UI 4 3 4 4 Verifying the Configuration 4 11 Chapter 5 Shutting Down the WS5100 5 1 Shutting Down From the Switch Web UI 5 1 5 2 Shutting Down From the CLI 5 2 Chapter 6 Regulatory Information Chapter 7 Part Numbers and Support Chapter 8 End User License Agreement ...

Страница 5: ...ucing wireless networking complexity by moving management out of the ceiling and into the wiring closet In addition through the use of Motorola s patented Virtual AP architecture the WS5100 lets you create multiple WLANs without changing or adding to the existing wired network infrastructure This Installation Guide is written for the network device installer 1 1 Package Contents Inspect the packag...

Страница 6: ...onnecting it to the power source Verify any device connected to this unit is properly wired and grounded Connect all power cords to a properly wired and grounded electrical circuit Verify the electrical circuits have appropriate overload protection Attach only approved power cords to the device Motorola strongly recommends the use of an Uninterruptible Power Supply UPS that supports the WS5100 pow...

Страница 7: ...ite Preparation Consult your site survey and network analysis reports to determine specific equipment placement port capacity power drops etc Assign installation responsibility to the appropriate personnel Identify where all installed components are located Verify appropriate rack mounting requirements Provide a sufficient number of power drops for your equipment Ensure adequate dust free ventilat...

Страница 8: ...WS5100 Series Switch Installation Guide 1 4 ...

Страница 9: ...ified as appropriate for the country of operation Width 48 1 cm 18 93 in with mounting brackets 42 9 cm 16 89 in without mounting brackets Height 4 39 cm 1 73 in Depth 40 46 cm 15 93 in Weight 6 25 kg 13 75 lbs Max Power Consumption 100 VAC 50 60 Hz 3A 240 VAC 50 60 Hz 1 5A Operating Temperature 10 C 35 C 50 F 95 F Operating Humidity 5 85 without condensation ...

Страница 10: ...r capacity for the data processing equipment must be purchased 2 3 Cable Requirements To connect the WS5100 to the LAN and the WLAN you need two Category 6 Ethernet cables not supplied one for each of the two Ethernet ports on the front of the switch To connect the WS5100 to a computer running a serial terminal emulator program the configuration computer you need the console cable supplied with th...

Страница 11: ...d Over and Adopting Ports Blue blinking Blue blinking Active Not Failed Over Blue blinking Amber solid Event Top LED Bottom LED POST failed critical error Red blinking Red blinking Software initialization failed Amber solid Off Country code not configured Note During the first setup the LEDs will remain in this state until the country code is configured Amber solid Amber blinking No access ports h...

Страница 12: ...WS5100 Series Switch Installation Guide 2 4 ...

Страница 13: ...Hardware Setup 3 1 Installing the WS5100 To install the WS5100 switch in a rack 1 Attach the rack brackets to the sides of the device The rack brackets are ambidextrous 2 Attach the brackets to the rack ...

Страница 14: ...panel of the WS5100 4 Using the supplied console cable connect the WS5100 serial port to an RS 232 DB 9 serial port on a separate computer the configuration computer 5 On the configuration computer configure a terminal emulation application such as HyperTerminal as follows The WS5100 does not need to be fully deployed into the wired or wireless network to complete the installation steps outlined i...

Страница 15: ... top LED is solid blue but the bottom LED is unlit After the software has finished initializing the top LED is blinking amber and the bottom LED is solid amber The WS5100 is ready to be configured as described in the next chapter Other LED codes indicate the presence or absence of access ports different standby states and so on A guide to the WS5100 LEDs codes is provided in LED Codes on page 2 2 ...

Страница 16: ...WS5100 Series Switch Installation Guide 3 4 ...

Страница 17: ...ough the serial port and powered on the switch the terminal emulation window displays a series of diagnostic messages which you can ignore after which it displays the WS5100 Series user name prompt Use the name CLI to continue user name cli Next you are taken to the CLI login Log in as admin with the password superuser NOTE If the user name prompt isn t displayed press Enter until it appears NOTE ...

Страница 18: ... to the switch by the DHCP server 4 2 2 Setting Static IP Information Setting a fixed IP address for the VLAN 1 interface on the switch will automatically disable DHCP To set the IP address for the switch ws5100 enable ws5100 configure terminal Enter configuration commands one per line End with CNTL Z ws5100 config interface vlan 1 ws5100 config if ip address w x y z 24 ws5100 config if exit ws510...

Страница 19: ...erify the preliminary configuration described in this section refer to Verifying the Configuration on page 4 11 4 3 1 Web UI Requirements The WS5100 Series Web UI is accessed using Internet Explorer version 5 5 and SUN JRE Java Runtime Environment 1 5 Later versions of IE and the SUN JRE are also supported Refer to the Sun Microsystems Web site for information on downloading JRE To prepare Interne...

Страница 20: ...rd superuser Both are case sensitive The Switch screen displays Click the Show Dashboard button to display an overall indicator of switch health Once the switch is fully configured the dashboard is the central display for the user to view the version of firmware running on the switch quickly assess the last 5 alarms generated by the switch view the status of the switch s Ethernet connections and v...

Страница 21: ...Configuration 4 5 3 Close the WS5100 Series Switch Dashboard The WS5100 Switch screen displays with the Configuration tab selected ...

Страница 22: ...peration Selecting the country is central to legally operating a WS5100 Each country has its own regulatory restrictions concerning electromagnetic emissions and the maximum RF signal strength that can be transmitted To ensure compliance with national and local laws be sure to set the country accurately CAUTION The switch cannot adopt access ports until the country code is set Failure to set the p...

Страница 23: ...reless LANs screen displays with existing WLANs appearing within the table 32 disabled WLANs are available to select enable and edit to better suit the needs of switch managed network For the purposes of the preliminary configuration described within this guide a single WLAN will be enabled and edited to configure a secure association with a single MU CAUTION The WLANs initially displaying within ...

Страница 24: ...e table and click the Enable button at the bottom of the screen A green checkmark within the Enabled column defines the WLAN as enabled A red x within the Enabled column defines the WLAN as disabled 9 Select the newly enabled WLAN and click the Edit button The Wireless LANs Edit screen displays ...

Страница 25: ...figuration a WEP 128 based encryption scheme will be defined to secure the data traffic between the WS5100 and its associated MU s 12 Within the Encryption field select the WEP 128 checkbox and click the Config button The WEP 128 KeyGuard screen displays with fields to define the Pass Key used to generate WEP keys These keys must be the same between the WS5100 and its associated MU to encrypt pack...

Страница 26: ... can be either a hexadecimal or ASCII string For WEP 128 104 bit key the keys are 26 hexadecimal characters in length or 13 ASCII characters Select one of the keys for activation by clicking its radio button 15 Click OK to save the settings within the WEP 128 KeyGuard screen 16 Click OK within the Wireless LANs Edit screen to save the changes made within this screen 17 Click the Save button in the...

Страница 27: ...nd WEP settings defined for the WS5100 5 Verify the MU has been associated by selecting Network Mobile Units from the main menu The Mobile Units screen should display the MU s MAC address and network address information If the MU does not display within the Mobile Units screen verify the MU s ESSID and encryption settings are properly set 6 If more information is required for the target MU select ...

Страница 28: ...WS5100 Series Switch Installation Guide 4 12 ...

Страница 29: ...tion tab and click the Shutdown button 3 Follow the prompts displayed by the Web UI to safely shutdown the WS5100 WARNING An improper shutdown can render the WS5100 inoperable such that it may require service by Motorola Support Do not remove AC power or turn off the WS5100 by toggling the on off switch on the back of the device without first following the shutdown procedure outlined above An abru...

Страница 30: ...going down NOW Connection is closed by administrator WIOS_SECURITYMGR 395 DNSALG Shutting down WIOS_SECURITYMGR 395 FTPALG Shutting down The system is halted NOTE The WS5100 will power off after issuing a halt command through a software toggle of the power supply Be sure to flip the power switch to the Off position If the power cord is removed and reinstalled or power is lost and restored the swit...

Страница 31: ...tion will make the operation of this device illegal WARNING This regulatory section applies only to the WS5100 For more information refer to Part Numbers and Support on page 7 1 All Motorola devices are designed to be compliant with rules and regulations of locations they are sold in and are labeled as required Any changes or modifications to Motorola equipment not expressly approved by Motorola a...

Страница 32: ... this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense Radio Frequency Interference Requirements Canada This Class A digital apparatus complies with Canadian ICES 003 Cet appareil numérique de la classe A est conforme à la norme NMB 003 du Canada Marking and European Economic Area EEA Stat...

Страница 33: ... 18 port WS5100 Wireless Switch WS 5100 18 WWR 24 port WS5100 Wireless Switch WS 5100 24 WWR 30 port WS5100 Wireless Switch WS 5100 30 WWR 36 port WS5100 Wireless Switch WS 5100 36 WWR 42 port WS5100 Wireless Switch WS 5100 42 WWR 48 port WS5100 Wireless Switch WS 5100 48 WWR Redundant WS5100 Wireless Switch WS 5100 RS WWR 6 port Upgrade WS 5100 UC WW ...

Страница 34: ...or fax within the time limits set forth in support agreements If you purchased your Enterprise Mobility business product from a Motorola business partner contact that business partner for support Customer Support Web Sites Motorola s Support Central Web site located at www symbol com support provides information and online assistance including developer tools software downloads product manuals and...

Страница 35: ...Y PERSON OR ENTITY 1 LICENSE GRANT Subject to the terms of this Agreement Motorola Inc and or its subsidiaries Licensor hereby grants Licensee a limited personal non sublicensable non transferable nonexclusive license to use the software that Licensee is about to download or install and the documentation that accompanies it collectively the Software for Licensee s personal use in connection with h...

Страница 36: ... be accessed through use of the Software is the property of the respective content owner and may be protected by applicable copyright or other intellectual property laws and treaties This EULA grants you no rights to use such content As a condition to Licensee s use of the Software Licensee represents warrants and covenants that Licensee will not use the Software i to infringe the intellectual pro...

Страница 37: ...utory including but not limited to any if any implied warranties or conditions of merchantability of fitness for a particular purpose of lack of viruses of accuracy or completeness of responses of results and of lack of negligence or lack of workmanlike effort all with regard to the Software and the provision of or failure to provide Support Services ALSO THERE IS NO WARRANTY OR CONDITION OF TITLE...

Страница 38: ...t tolerant and is not designed manufactured or intended for use or resale in on line control equipment in hazardous environments requiring fail safe performance such as but not limited to the operation of nuclear facilities aircraft navigation or communication systems air traffic control life support machines or weapons systems in which the failure of the Software could lead directly or indirectly...

Страница 39: ...ry so that this Agreement shall otherwise remain in full force and effect No waiver or modification of this Agreement will be binding upon a party unless made in writing and signed by a duly authorized representative of such party and no failure or delay in enforcing any right will be deemed a waiver This Agreement shall be governed by the laws of the State of New York without regard to the confli...

Страница 40: ...WS5100 Series Switch Installation Guide 8 6 ...

Страница 41: ......

Страница 42: ...MOTOROLA INC 1303 E ALGONQUIN ROAD SCHAUMBURG IL 60196 http www motorola com 72E 100956 01 Revision A June 2007 ...

Отзывы: