3-16
Configuring a Vanguard Router
Configure LAN Connections
LAN Connection Table Record Parameters
Introduction
This section describes the LAN Connection Record parameters. Any parameter with
an asterisk (*) requires a Node boot; changes to other parameters require a Table
Record boot.
Parameters
From the LAN Connection Table Record, you can configure the following
parameters:
Entry Number
Range:
1 to n, where n = 32 to 2000 (depending on the product)
Default:
1
Description:
Specifies the entry number used to reference this table record. The
allowable range of values reflect the maximum number of LAN
connections set in the LAN Connection Parameters menu.
*LAN Forwarder Type
Range:
ROUT, BRID, BROUT
Default:
ROUT
Description:
Specified if the LAN Connection is to pass bridged, routed, and/or
brouted traffic:
• BRID: Bridged LAN traffic is transported across this
connection.
• ROUT: Routed LAN traffic is transported across this
connection.
• BROUT: Both bridged and routed LAN traffic are transported
across this connection.
Boot Type:
Changes to this parameter require a Node Boot to take effect.