Status Registers
V.3600
10-7
Escape Sequence Pause — S12
The escape sequence to return to command mode from data mode
requires two pauses, one before and one after the escape characters.
The pauses prevent the modem from responding to a character sequence
which might contain the escape sequence as part of its normal data
transmission.
S12
contains the pause interval in 0.02 second increments. The factory
setting is 50, equivalent to 1 second (50 x 0.02 sec). When
S12
is 0,
timing is not a factor.
The timing between the 3 escape characters must be less than the pause
interval or the escape sequence will not be detected. The data rate also
affects the timing and must be taken into account when changing the
pause interval.
To disable the escape command, set
S2
to a value greater than 127
instead of changing
S12
. Values between 15 and 255 may be used for
S12
.
S13
Not used