V.25 bis Autodialer
V.3600
11-15
LSO
List stored options.
The separator {sep} for BISYNC is an
<etb><sp><sp><stx>LSO<sp>
sequence for the sync format (the last
LSO
string terminates with
<etx>
per V.25 bis). For synchronous bit oriented operation, each
LSO
string
is treated as an individual message per V.25 bis.
If no parameters follow, all stored options are sent to the DTE as
LSOxxx;ooo{sep}xxx;ooo...
Each value must be padded with leading zeros so that each field has
three characters. Option zero would be sent as
LSO000;000
If only an address follows the command, the single requested option is
sent to the DTE as
LSOxxx;ooo
If address and count follow the command, the requested count of
options starting with the specified address are sent to the DTE as
LSOxxx;ooo{sep}xxx;ooo...
Options
You can change the options for the V.25 bis autodialer using the
PRO
command or list them using the
RLO
command. Options are listed in
Table 11-2. V.25 Autodialer Options
Option
Definition
Settings
Default
002:
Intermediate call progress messages
0 - Disable
1 - Enable
0
003:
Blind dial
0 - Disable
1 - Enable
0
007:
Long space disconnect
0 - Disable
1 - Enable
1
Содержание V.3600
Страница 8: ......
Страница 27: ...Installation V 3600 2 3 Figure 2 2 Digital Interface Signals ...
Страница 34: ......
Страница 40: ......
Страница 52: ......
Страница 98: ......
Страница 110: ......
Страница 192: ......
Страница 194: ......
Страница 197: ...Hardware Options V 3600 C 3 Figure C 2 shows the jumper location Figure C 2 Jumper Location for Ground Option ...
Страница 202: ......
Страница 234: ......
Страница 256: ......