SC 4812T-MC BTS READ-ME-FIRST (Optimization/ATP)
68P64115A21–B
Sept 2003
1X SC 4812T-MC Multicarrier BTS Optimization/ATP
RMF-7
2-Carrier, 6-Sector Configuration (requires 12 measurements)
Use this procedure to take measurements with both carriers enabled.
Sector
Carrier 1
Carrier 2
Sector
Carrier 1
Carrier 2
1
BBX-1
1
BBX-7
2
BBX-2
2
BBX-8
3
BBX-9
3
BBX-3
4
BBX-4
4
BBX-10
5
BBX1–11
5
BBX-5
6
BBX1–12
6
BBX-6
Procedure:
1. Enable the following BBXs:
– BBX-1 (C1–S1)
– BBX-2 (C1–S2)
– BBX-4 (C1-S4)
– BBX-9 (C2–S3)
– BBX-11 (C2-S5)
– BBX-12 (C2-S6)
2. Measure TX power from each of all 6 sectors.
3. Disable BBXs.
4. Enable the following BBXs:
– BBX-3 (C1–S3)
– BBX-5 (C1-S5)
– BBX-6 (C1-S6)
– BBX-7 (C2–S1)
– BBX-8 (C2–S2)
– BBX-10 (C2-S4)
5. Measure TX power from each of all 6 sectors.
6. Disable BBXs.