4.5 Supplying Power to the RFS7000 Series RF Switch
1.
Plug an approved AC power cord into the power connector at the back of the RFS7000 Series RF
Switch.
2.
Plug the cord into a standard AC outlet with a voltage range of 100 to 240 VAC.
.
Terminal Type
VT-100
Port
COM port
Terminal Settings
19200bps transfer rate
8 data bits
no parity
1 stop bit
no flow control
no hardware compression
WARNING!
An improper shutdown can render the RFS7000 Series RF Switch
inoperable such that it could require service by Motorola Solutions
Support. Do not remove AC power without first following the shutdown
procedure. An abrupt loss of power can corrupt the information stored on
the device.