Installation
B
QIP7000 (P2) Series Hybrid QAM/IP HD Set-top Terminal • Installation Manual
20
574702-001 a
This document is uncontrolled pending incorporation in a Motorola CMS
Table 6 – ONT1000M Connections
Key
Name
Description
1 Telco
ground
terminal
Connects the ONT1000M and the subscriber’s telephone, data, and
cable TV wiring networks to protective ground at the electrical service
ground electrode.
2
Fiber in
OptiFit connector provides input to the ONT1000M from the PON
network.
3 UPS
input
terminal strip
Connects the ONT1000M to an external Uninterruptible Power Supply
(UPS), as follows:
•
POS
— connects to the +12 VDC output terminal on the external
power supply (UPS).
•
NEG — connects to the –RTN output terminal on the external power
supply (UPS).
•
Signal RTN — connects to the SIG RTN output terminal on the
external power supply (UPS).
•
ON BATT — ONT1000M is operating off of the battery. Connects to
the ON BATT terminal on the UPS.
•
REPLACE BATT
— battery present but not operational. Connects to
the
BATT MISSING
terminal on the UPS.
•
LOW BATT
— battery low, needs changing. Connects to the
LOW
BATT
terminal on the UPS.
•
Using a UPS is optional for a network-powered ONT1000M.
4 Telephone
terminal strip
Termination point for subscriber’s telephone lines. These are insulation
displacement type connectors (IDCs) and serve as input for four
separate lines.
5 Ethernet
connection
RJ-45 Ethernet high-speed data connection to the subscriber’s
computer.
6
Cable out
Cable TV output for distribution of video services to the customer
premises.