16
Cable Preparation and Installation
Step 4:
When the gland body has been fitted, tighten the gland back shell.
Caution!
Do not over tighten the gland back shell.
Gland on the right-hand side has been over tightened. As a result, the internal seal
and structure have been damaged:
Step 5:
Should it be necessary to disconnect the cable at the ODU (or PTP LPU), this can
be achieved by removing the gland back shell first. Then, wiggle the cable to release the
tension of the gland body as shown in the figure below. Then you can unscrew the gland
body and depress the RJ45 locking tab with a small screwdriver.
Apply small movements to the cable until you see a gap here before
unscrewing the gland body.
More information:
PTP 300 Series User Guide
or
PTP 500 Series User Guide