42
Englis
h
Language Menu
Figure 14:
Language Menu
The charger display supports North American English only.
Analyzer Mode
You can enter Analyzer Mode by firmly pressing the OK button from
more than 3 seconds (the hold time is adjustable.) The Analyzer Mode
features described are associated with charger software version 1.05.
Pressing OK displays data available from the battery or charging
pocket on the display adjacent to the Pocket, followed by Charger
software version.
• Press the Right Arrow to sequence through the data as represented.
• Press the Left Arrow to sequence through the data in reverse order.
• Press Back to exit from Analyzer Mode. Press OK to confirm exit.
If no Keypad button is pressed for 10 minutes, then the charger exits
Analyzer Mode and returns to normal message displays.
While in Analyzer Mode, if the battery is removed and replaced by
another battery, the last parameter displayed for the first battery will be
the first parameter displayed for the second battery. For example, while
Battery IMPRES Cycles is being displayed, the IMPRES 2 or IMPRES
battery is removed from Pocket 1 and a different IMPRES 2 or IMPRES
battery is inserted into Pocket 1. The first parameter display for the
second battery will be Battery IMPRES Cycles.
MN003555A01.book Page 42 Wednesday, February 14, 2018 2:40 PM
Содержание PMPN4283
Страница 2: ......
Страница 54: ...52 English Figure 23 Lost Battery by Location Figure 24 Charger Pocket Utilization ...