Manually Terminating Calibration/Reconditioning
At any time during IMPRES or IMPRES 2 battery discharge
(Steady
Amber)
, Calibration/Reconditioning may be terminated. Perform the
following steps:
1. Remove the battery from the charger pocket.
2. Within five seconds, reinsert the battery into the charger pocket.
Battery discharge immediately terminates, and Normal battery
charging starts. The LED indicates Charge Status.
End-of-Service-Life Indication
As batteries are used, normal wear reduces available capacity. At the
successful completion of Calibration/Reconditioning, IMPRES
chargers compare IMPRES battery capacity to the battery Rated
Capacity. When the capacity is at a very low value, the IMPRES battery
may be nearing its End of Service. The IMPRES battery remains
usable. In some scenarios, it may be desirable to deploy the battery to
someone who does not require large battery capacity to complete a
work shift.