![Motorola MVME2600 Series Скачать руководство пользователя страница 156](http://html.mh-extra.com/html/motorola/mvme2600-series/mvme2600-series_installation-and-use-manual_245418156.webp)
6-4
Computer Group Literature Center Web Site
CNFG and ENV Commands
6
Remote Start Method Switch [G/M/B/N] = B?
The Remote Start Method Switch is used when the
MVME2600/MVME3600/MVME4600 is cross-loaded from another
VME-based CPU, to start execution of the cross-loaded program.
Probe System for Supported I/O Controllers [Y/N] = Y?
Auto-Initialize of NVRAM Header Enable [Y/N] = Y?
G
Use the Global Control and Status Register to pass
and start execution of the cross-loaded program. This
selection is not applicable to the
MVME2600/MVME3600 boards.
M
Use the Multiprocessor Control Register (MPCR) in
shared RAM to pass and start execution of the cross-
loaded program.
B
Use both the GCSR and the MPCR methods to pass
and start execution of the cross-loaded program.
(Default)
N
Do not use any Remote Start Method.
Y
Accesses will be made to the appropriate system
buses (for example, VMEbus, local MPU bus) to
determine the presence of supported controllers.
(Default)
N
Accesses will not be made to the VMEbus to
determine the presence of supported controllers.
Y
NVRAM (PReP partition) header space will be
initialized automatically during board initialization,
but only if the PReP partition fails a sanity check.
(Default)
N
NVRAM header space will not be initialized
automatically during board initialization.