Application Deployment for WinCE 5.0 7 - 19
Creating a Splash Screen
The source bitmap files used to create the default splash screens for the mobile computer are supplied with the
DCP for MC9090c50. These files can be modified using any of the standard windows image editors, allowing
customization for particular customers.
To create a custom splash screen, perform the following steps:
There is no more heap
space available
-14
There is no more heap space available for the download procedure.
Restart IPL and retry the download. If the failure persists, contact
service with details of what is being downloaded.
Insufficient data available
to complete record
-21
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
Invalid Symbol HEX file
-23
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
Unrecognized or
unsupported HEX record
-24
The Symbol HEX file being downloaded contains an invalid or
unrecognized HEX record. Ensure the file is in proper Symbol HEX file
format.
Invalid data in HEX file
-25
The Symbol HEX file being downloaded contains invalid data. Ensure
the file is in proper Symbol HEX file format with valid HEX data.
Exceeded max size
-26
The download file is too large to fit into the space allocated for it. Either
make the file smaller or increase the space allocated for it by altering
the partition table.
Partition is not valid on
this device
-27
The downloaded file specifies a partition entry that does not exist on
the device. Only download files that are valid for this device, or change
the partition table so that the new file is valid on the device.
Wrong destination code
-28
A specific partition was chosen from the Main Menu (not Auto Select)
but the file selected for download was for another partition. Ensure that
the partition selected from the Main Menu matches the file selected for
download.
File type does not support
IPL Auto Select
-29
Monitor, Power Micro and Partition Table cannot be loaded with Auto
Select. Select the appropriate area, and try again.
Non-contiguous record
found
-30
A Symbol HEX file download was attempted but the HEX file is invalid.
Ensure the file is in Symbol HEX file format.
Timed Out - No data
-31
IPL was waiting for data from the source device but timed out before
receiving any. Check the source device connectivity and retry.
Fail: Buffer Overrun
-32
The serial port device could not keep up with incoming data. Retry the
serial download with a lower baud rate.
Partition Table not Valid
-33
The size of flash memory is different than that described in the partition
table. Retry the download with the correct partition table file.
Invalid file format
-34
The file format is invalid. Only Symbol HEX files are supported by IPL.
Table 7-4
IPL Errors (Continued)
Error Text
Error
Number
Probable Cause
Содержание MC909X
Страница 1: ...MC909X Mobile Computer Integrator Guide ...
Страница 2: ......
Страница 3: ...MC909X Integrator Guide 72E 72216 06 Rev A December 2007 ...
Страница 6: ...iv MC909X Mobile Computer Integrator Guide ...
Страница 24: ...xxii MC909X Integrator Guide ...
Страница 150: ...4 42 MC909X Integrator Guide ...
Страница 220: ...8 14 MC909X Integrator Guide ...
Страница 229: ...Staging and Provisioning 9 9 Figure 9 13 Staging Complete Window Press the left function key to exit ...
Страница 234: ...9 14 MC909X Integrator Guide Figure 9 21 Package List Window Tap OK to return to the Main Menu ...
Страница 241: ...Staging and Provisioning 9 21 Figure 9 32 UnHide UI Selection ...
Страница 252: ...9 32 MC909X Integrator Guide ...
Страница 266: ...10 14 MC909X Integrator Guide ...
Страница 300: ...B 24 MC909X Integrator Guide ...
Страница 314: ...Glossary 14 MC909X Integrator Guide ...
Страница 321: ......