![Motorola iDEN i580 Скачать руководство пользователя страница 86](http://html.mh-extra.com/html/motorola/iden-i580/iden-i580_field-service-manual_243023086.webp)
FIELD LEVEL TEST MODES AND PROCEDURES:
Reset Log Test
68P80401P05
71
8.12
Reset Log Test
Use this test to check the reset log in the unit.
To perform the reset log test:
1.
Power on the unit and wait until registration is complete.
2.
If the unit does not have the latest software version, reflash (reprogram) the unit.
If the unit attempts to reset, perform the Reset test (see page 8-11).
3.
Enter Trace Mode (see page 6-1). The
Unit Info
display appears.
4.
Scroll down and highlight
Resets
, and then press
View
to view the
Resets
display.
5.
Look for and record any reset errors.
If the log contains reset errors, perform the Reset test.
6.
Place a dispatch call.
7.
Look for, and record, any reset errors.
If the unit attempts to reset, perform the Reset test.
8.
Place an interconnect call.
9.
Look for and record any reset errors.
If the unit attempts to reset, perform the Reset test.
NOTE:
If the customer agrees, set the Auto Lock feature. This feature helps detect reset
conditions.