BASIC LEVEL TEST MODES AND PROCEDURES:
Test Mode Test Procedures
68P80401P05
37
The Audio Loopback test time is approximately 3 minutes:
1. Enter Test Mode.
2. With the Test Mode screen displayed, press Menu. The right option key changes to
Edit
.
3. Press the option key under Edit. The right option key changes to
Change
.
4. Press the
Change
option key.
5. Using the bottom scroll key, scroll down the list until
AUDIO1 or 800AUD1
is displayed.
6. Press the
Select
option key.
7. Press the
Back
option key.
8. Press Menu.
9. Press the
Start
option key to begin the actual audio test in the TX On mode.
10. Talk into the microphone. The audio from the earpiece should sound clear.
If there is a problem with the microphone or the earpiece, power down the unit and repeat the
test. If the problem persists, send the unit to the field-level Support Facility.
11. Press the
Tx Off
key, and repeat the previous step.
12. Press the
Stop
key to end the test.
6.2.2
ESN and IMEI Matching Test
Use this test to verify that the electronic serial number (ESN) matches the International Mobile
Equipment Identifier (IMEI) on the Serial Number label located on the chassis of the unit.
The ESN/IMEI Matching test time is approximately 6 minutes:
1. Power up the unit. Wait until the power-up sequence is complete before continuing.
2. Enter Debug Mode. The
Unit Info
display appears.
3. Scroll down until the
IMEI/SIM ID
choice is highlighted, then press
View
to view the
IMEI/
SIM ID
display.
4. Write down the digits shown in the IMEI line.
5. Verify that this number matches the IMEI on the Serial Number label. The last zero on the label
will be missing.
If the numbers do not match, send the unit to the field level of service.
6.2.3
Debug Check
Use this check to monitor (measure) the data in an
i
580 unit.