![Motorola iDEN i580 Скачать руководство пользователя страница 36](http://html.mh-extra.com/html/motorola/iden-i580/iden-i580_field-service-manual_243023036.webp)
BASIC LEVEL CHECKS AND SELF TESTS:
Basic-Level Test Checklist
68P80401P05
21
5.3
Basic-Level Test Checklist
Use the following checklist to ensure that all the necessary tests are performed and to provide a
tracking mechanism in case the unit is sent to the next level of service. Check the appropriate box for
each test performed and indicate whether or not the test was completed successfully.
5.4
Preventive Maintenance
Although the unit does not require a scheduled preventive maintenance program, a visual inspection
and cleaning is recommended before testing begins.
NOTE:
Do not use aerosol sprays, tuner cleaners, or other chemicals to clean the unit. Damage to
the plastic surfaces might occur.
To clean the unit takes approximately 3 minutes:
1. Prepare a
0.5%
solution of a mild dishwashing detergent and water.
2. Apply the solution sparingly to the external surfaces of the unit with a soft, absorbent cloth.
Prevent moisture from getting inside the unit.
Table 5-1. Basic-Level Test Checklist
Done
Test
Pass
Fail
Shock and Pressure
SIM Card Swap
Accessory Swap
Lockup
Battery Connections
Voltage Recognition
GPS Receiver
Passcode
Programming Menu Settings
Call Performance
Audio Loopback
ESN and IMEI Matching
Debug/Trace Mode
Model Assembly Test Mode
Codeplug Error Messages
Codeplug Troubleshooting
Software Utility Procedure