Mesh Enabled Architecture
EWR/PWR Users Guide
2.6.1 PWR Installation Procedure
The following instructions describe the PWR6300 hardware installation procedure:
1. Mount the PWR in a traffic cabinet or kiosk. The device is not waterproof and should be
reasonably protected from moisture and other exposed outdoor environments.
2. Connect the antenna to the N-type connector.
3. Insert the Power Plug into Power Connector.
4. Verify the transceiver and Ethernet MAC address have been recorded in
Section 2.4.3
, as it
will be required to configure and test the device.
5. The Test Port is unused during deployment.
Figure 2-8
PWR6300 Cabinet Mounting
2.7 Device Deployment Considerations
When deploying the EWR6300 or the PWR6300 consider the following:
•
The antenna should be a minimum of 30 inches from any nearby metal poles to avoid
distortion of the RF pattern.
•
The antenna must have a separation distance of at least 2 meters from the body of all
persons and must not be co-located or operating in conjunction with any other antenna or
transmitter.
•
Users and installers must be provided with antenna installation and transmitter operating
conditions to satisfy RF exposure compliance.
•
Typically, the EWR and the PWR are distributed within a network and are used as
subscriber devices. A rule of thumb is to deploy 2-3 hop networks to optimize range, latency,
and throughput to subscriber devices.
•
It
is
required
that the EWR/PWR chassis be grounded to minimize the possibility of ESD
(electrostatic discharge) induced damage.
11