8-4
6864110R66-O
March, 2001
Programming Professional Series Radios for use with a Basic Repeater Controller
CDR500 & CDR700 Repeater Service Manual
Bi-directional Repeater
NOTE
In the United States of America, the
Professional Series radios may not be
used legally as the transmit radio in a
UHF (450 to 512 MHz) repeater or base
station application with 12.5 kHz chan-
nel spacing. The
±
2.5-ppm frequency sta-
bility capability of the radio does not
meet the requirements of Part 90 of the
Rules and Regulations of the Federal
Communications Commission (FCC). In
other countries, check local frequency
stability requirements before placing a
Professional radio based repeater or base
station in operation.
18. Enter the transmit frequency for the repeater
in the “Rx” area at “Frequency (MHz)”.
19. Select the receiver “Squelch Type:” as “CSQ”
(Carrier SQuelch).
20. Enter the transmit frequency for the repeater
in the “Tx” area at “Frequency (MHz)”.
21. Select the transmitter “Squelch Type:” based
upon the type of operation that is required
(CSQ, TPL or DPL). Your screen should
appear similar to Figure 8-8.
22. Enter any other special programming require-
ments in the appropriate windows.
23. Assign the personality to a zone in the “Per-
sonality Assignment to Zone” selection win-
dow.
24. Program the transmit radio.
Basic (R*I*C*K) Unidirectional Repeater -
S2 DIP Switch Settings
Set the 12 positions of DIP switch S2 according to the
following information:
1.
The repeater is unidirectional: S2-1 “OFF”.
2.
The pin 8 COR signal of the receive radio will
key the transmit radio: S2-2 “OFF” and S2-3
“ON”.
3.
There isn't any remote control to be used with
the repeater: S2-4 “OFF”.
4.
We will use normal receiver and transmitter
audios from the radios; S2-5 “OFF”, S2-6
“ON”, S2-8 “OFF” and S2-9 “OFF”.
5.
The audio gate in the Basic controller will be
used: S2-7 “OFF”.
6.
The unidirectional repeater will use dropout
delay: S2-10 “OFF” for 3-second delay or
“ON” for 1.5-second delay. S2-11 “OFF” in
both cases.
7.
The configuration is standard: S2-12 “OFF”.
The DIP switch should look similar to Figure 8-9.
Basic Adjustments
See "Basic Adjustments" at the end of this section for
further instructions.
Bi-directional Repeater
Professional Series Radios
Receive Radio Programming
1.
Read the Professional Series receive radio.
2.
After the radio is read, select “Radio Configu-
ration” from the opening CPS “Tree View”
window.
3.
Click the “Basic” tab.
4.
If necessary, uncheck the “Hook (HUB)
Defeats PL” selection box. Your screen should
appear similar to Figure 8-1 on page 8-1.
5.
Click the “Accessory Configuration” tab.
6.
Click the “Rx Audio Type:” dropdown arrow
button. Select “Filtered Audio”.
Figure 8-8.
Conventional Personality, Basic,
Transmit Radio
Содержание CDR500
Страница 1: ...CDR500 Wall Mount Repeater CDR700 Desktop Repeater Service Programming Manual 6864110R66 O ...
Страница 8: ...vi 6864110R66 O March 2001 Table of Contents CDR500 CDR700 Repeater Service Manual ...
Страница 46: ...3 12 6864110R66 O March 2001 CDR700 Desktop Repeater Station CDR500 CDR700 Repeater Service Manual Repackaging ...
Страница 98: ...13 14 6864110R66 O March 2001 Troubleshooting CDR500 CDR700 Repeater Service Manual ...