44
May 15, 2001
6881038B20
Troubleshooting
Product Family B89
Programming: Software Upgrade and Flexing
Contact your local technical support engineer for information about equipment and
procedures for flashing and flexing.
11. Real Time Clock resetting when
standard battery is removed.
Lithium button cell in the display board
may be depleted.
Replace the RTC battery as described in the
procedures. Check RTC time does not reset.
12. No or weak audio when using headset. a) Headset not fully pushed home.
Ensure the headset plug is fully seated in the
jack socket.
b) Faulty jack socket on transceiver
board assembly.
Replace the transceiver board assembly (refer
to 1c). Verify that the fault has been cleared and
reassemble the unit with the new transceiver
board assembly.
Table 3. PF A28 Telephone: Level 1 and 2 Troubleshooting Chart (Continued)
SYMPTOM
PROBABLE CAUSE
VERIFICATION AND REMEDY