Chapter 3: AT Commands Reference
April 15, 2008
G24-L AT Commands Reference Manual
3-267
The following table shows the Set Event List parameters.
Note:
Each language code consists of a pair of alphanumeric characters, defined in ISO 639 [4].
Each character is coded on one byte using the SMS default 7-bit coded alphabet, as
defined in TS 23.038, with bit 8 set to 0. For a list of language codes, refer to the section
that follows.
Table 3-189: Set Event List Parameters
<Parameter>
Description
<Result>
5
User Activity event
6
Idle Screen Available event
8
Language Selection event
9
Browser Termination event
<Data>
None User Activity event
None Idle Screen Available event
0
Browser Termination event (User terminated)
1
Browser Termination event (Error terminated)
4
Language Selection event, with string coded as follows:
Byte(s)
Description
Length
1
Language tag
1
2
Length=’02’
1
3-4
Language
2