Access
3-186
G24-L AT Commands Reference Manual
April 15, 2008
Example
AT+CLCK=?
+CLCK: ("SC","AO","OI","OX","AI","IR","AB","AG","AC","FD")
OK
AT+CLCK="SC",2
+CLCK: 0
OK
AT+CLCK="SC",1
+CME ERROR: operation not allowed
AT+CLCK="SC",1,"incorrect password
+CME ERROR: incorrect password
AT+CLCK="SC",1,"correct password"
OK
(From now SIM Card is locked and PIN is requested on power up)
AT+CLCK="AB",0,"incorrect password"
+CME ERROR: incorrect password
AT+CLCK="IR",2
+CLCK: 0,1
+CLCK: 0,2
+CLCK: 0,4
+CLCK: 0,8
OK
AT+CLCK="IR",1,"correct password" //<classx> is defaulted to 7 when not specified
OK
AT+CLCK="IR",2
+CLCK: 1,1
+CLCK: 1,2
+CLCK: 1,4
+CLCK: 0,8
OK
AT+CLCK="OI",2
+CLCK: 0,1
+CLCK: 0,2
+CLCK: 0,4
+CLCK: 0,8
OK
AT+CLCK="OI",1,"correct password",3
<class>
Sum of integers, each representing a class of information <class>. Only applies to call
barring related facilities.
1
Voice (telephony)
2
Data (refers to all bearer services)
4
Fax (facsimile services)
8
SMS (Short Message Services)
The default value is 7.
<status>
0
Inactive
1
Active
Table 3-124: +CLCK Parameters (Cont.)
<Parameter>
Description
Содержание AT Commands G24-L
Страница 4: ......
Страница 20: ...List of Tables xvi G24 L AT Commands Reference Manual April 15 2008 ...
Страница 56: ...AT Commands Summary 1 26 G24 L AT Commands Reference Manual April 15 2008 ...
Страница 402: ...Tools Overview 5 2 G24 L AT Commands Reference Manual April 15 2008 ...
Страница 441: ...W W Index April 15 2008 G24 L AT Commands Reference Manual Index 7 ...
Страница 442: ......
Страница 443: ......