A-14
Configure and Environment Commands
A
Configuring the IndustryPacks
ENV
asks the following series of questions to set up IndustryPacks
(IPs) on MVME162LX VMEmodules.
The MVME162LX Embedded Controller Programmer's Reference Guide
describes the base addresses and the IP register settings. Refer to
that manual for information on setting base addresses and register
bits.
Note
The IP2 ASIC on the MVME162LX supports up to four
IndustryPack (IP) interfaces, designated IP_a through
IP_d. The 700/800-series MVME162LX itself
accommodates two IPs: IP_a and IP_b. In the following
discussion, the segments applicable to IP_c and IP_d
are not used in the 700/800-series MVME162LX.
IP A Base Address
= 00000000?
IP B Base Address
= 00000000?
IP C Base Address
= 00000000?
IP D Base Address
= 00000000?
VMEC2 GCSR Group Base
Address
D2
Specifies the group address ($FFFFXX00)
in Short I/O for this board. Default = $D2.
VMEC2 GCSR Board Base
Address
00
Specifies the base address ($FFFFD2XX)
in Short I/O for this board. Default = $00.
VMEbus Global Time Out
Code
01
Controls the VMEbus timeout when the
MVME162LX is operating as system
controller. Default $01 = 64
µ
s.
Local Bus Time Out Code
02
Controls the local bus timeout. Default
$02 = 256
µ
s.
VMEbus Access Time Out
Code
02
Controls the local bus to VMEbus access
timeout. Default $02 = 32 ms.
Table A-1. ENV Command Parameters (Continued)
ENV Parameter and Options
Default
Meaning of Default
Содержание 700 Series
Страница 2: ......
Страница 3: ...700 800 Series MVME162LX Embedded Controller Installation and Use V162 7A IH1 ...
Страница 48: ...1 34 Board Level Hardware Description 1 ...
Страница 70: ...2 22 Hardware Preparation and Installation 2 ...
Страница 138: ...A 18 Configure and Environment Commands A ...
Страница 144: ...B 6 Disk Tape Controller Data B ...
Страница 146: ...C 2 Network Controller Data C ...
Страница 156: ...Index IN 6 I N D E X W watchdog timer 1 24 Z Z85230 serial communications controllers SCCs 3 6 ...