background image

v4.0

REV. 06/2016

EN

USER / INSTALLER MANUAL

MC15SC

Содержание MC15SC

Страница 1: ...v4 0 REV 06 2016 EN USER INSTALLER MANUAL MC15SC...

Страница 2: ...t sold by them Do not make any modifications to the operator components and or their accessories Before installation unplug the automatism from the source of power The installer must inform the client...

Страница 3: ...imum capacity 05 Output n 1 activated during closing gate 100mA maximum capacity CN3 CN4 Before proceeding to the control board configuration pay special attencion to the following parameters in the t...

Страница 4: ...center allows the connection of opening and closing limit switches both in NC The triggering of any limit switches causes the movement to stop immediately The triggering the limit switches will be sig...

Страница 5: ...mory is full To program new commands 01 Press SEL button once the CODE LED will begin to flash 02 Press once the transmitter button you want to program during 1sec 03 The LED CODE remains lit permane...

Страница 6: ...CONFIGURATION MAIN MENU 03 CONFIGURATION With this function can trigger deceleration decreasing the gate s movement velocity NOTE To perform this programming is necessary that the motors have limit sw...

Страница 7: ...button the times necessary until the LED T MOT PED starts to flash 02 Press SET button for 1 second to motor starts the opening If the motor doesn t start the opening invert wires connection 5 and 7...

Страница 8: ...ches the end of course does a brief inversion of output motor to stop immediately the motor eg Gates with inclination Activate LED ON deactivate LED OFF function 01 Activate the extended menu 1 see AC...

Страница 9: ...DS2 T MOT PUL Open Close BL STOP PUL Open BL Close T MOT PED Flashing simultaneously ON OFF T PAUSA Flashing simultaneously ON OFF ACCESSING THE EXTENDED MENU 2 To access the Extended Menu 2 options f...

Страница 10: ...MENU 2 Change the operating mode of the PUL and BL inputs 01 Turn on the extensive menu 2 see ACCESSING EXTENDED MENU 2 on page 8B 02 Press SEL and the T MOT LED will flash intermittently 03 Press the...

Страница 11: ...ngth knowing that the AUT PP LED ON corresponds to the minimum strength while the AUT PP CODE CODE PED INB CMD AP T MOT T MOT PED LEDs ON correspond to the maximum strength The control board is suppli...

Страница 12: ...and LED will flash alternately 02 With SEL button select the desired channel Code Sensor1 or Code Sensor 2 to pair the RTX 2252 sensor 03 It now has 10 seconds to press the SET button from the RTX 225...

Страница 13: ...ly and informs the base Alarm signal Tells the basis that the safety device is activated 03 CONFIGURATION RTX 2252 SENSOR MODULE OPTIONAL Setting the frequency A B C or D in RTX 2252 must be coinciden...

Страница 14: ...TION 04 COMPONENTS TEST SCHEMES FOR CAPACITORS To detect which components have problems during a sliding automatism installation sometimes it s necessary to conduct tests with a direct connection to a...

Страница 15: ...rmittent mode indicating the error When the photocells operation is corrected the control board returns to it s normal functioning This action by the control board allows to recognize failures in acco...

Страница 16: ...3 If the motor works the problem is from control board Pull it out and send it to our MOTORLINE technical services for diagnosis 4 If the motor doesn t work remove them from installation site and sen...

Страница 17: ...12 24V V R G B RG 24 CAP MOT 1 2 3 4 5 6 EN 06 CONNECTION SCHEME COMPONENT CONNECTION TO THE CONTROL BOARD Capacitor 2 COND 2 Capacitor 1 COND 1 Flashing Light Motor OPEN or Wall Button Key Selector A...