background image

5A

5B

1

5

6

2

3

4

7

8

EN

EN

02. OPERATOR

ACCESSORIES

PREPARING THE FOUNDATION PLATE

PRELIMINARY CHECKS

03. INSTALLATION

03. INSTALLATION

You must check the operator packing before installing the automated system.

1 •  

1 Motor

2 • 

1 Left limit switch plate

3 • 

1 Right limit switch plate

4 • 

4 Screw DIN912 M5x10

5 • 

1 Foundation plate

6 • 

4 Ground Fixation screw

7 • 

4 Motor Fixation screw

8 • 

2 Key

INSTALLATION TOOLS

POSITIONING THE OPERATOR

Fit the 4 supplied nuts, as shown in Fig. 07 

and Fig. 08, in the 4 holes of the plate.

1 • 

The foundation plate must be located 

as shown in Fig. 9a (right closing) or Fig. 9b 

(left closing) to ensure the rack and pinion 

match correctly.

2 • 

Put the foundation plate to the floor, 

using adequate expansion plugs and 

provide one or more tubes for routing the 

electric cables through the plate (Fig10 

and 11).

Using a level, check if the plate is perfectly 

horizontal.

Lay the electric cables to connect motor to accessories 

and power supply as shown in page 4B.

To facilitate making the connections, allow the cables 

to project by the required length for connection to the 

control board, transformer and etc (if provided).

Position the operator on the plate, using the supplied 

screws as shown in Fig. 12.

59mm

90º

90º

To ensure safety and an efficiently operating automated system, make sure the following 

conditions are applied:

• 

The structure of the gate must be suitable for being automated. In particular, check that the 

structure is sufficiently strong and rigid, and that its dimensions and weight conform to those

indicated in the technical specifications;

• 

Make sure that the gate slides without any inclination;

• 

Make sure that the gate moves uniformly and correctly, without any irregular friction during its

entire travel;

• 

The soil must permit sufficient stability for the expansion plugs securing the foundation plate;

• 

Remove any locks and lock bolts. We advise you to have any metalwork carried out before the

automated system is installed.

Fig. 07

Fig. 09a

Fig. 10

Fig. 12

Fig. 09b

Fig. 11

Fig. 08

Содержание OL1500

Страница 1: ...V1 0 REV 09 2022 OL1500 2000 110v EN USER S AND INSTALLER S MANUAL...

Страница 2: ...ystems This marking on the product or literature indicates that the product and electronic accessories eg Charger USB cable electronic material controls etc should not be disposed of as other househol...

Страница 3: ...in terms of usage of the product in a safe manner and who understands the risks and dangers involved Children shouldn t play with the product or opening devices to avoid the motorized door or gate fr...

Страница 4: ...er and do not use it until all safety conditions have been met In the event of tripping of circuits breakers of fuse failure locate the malfunction and solve it before resetting the circuit breaker or...

Страница 5: ...ey selector 8 Photocell column 9 Safety photocells 10 Antenna 11 Warning light 12 Safety edge Automated system for residential or industrial sliding gates with a maximum of 2000kgs It consists of a re...

Страница 6: ...s to connect motor to accessories and power supply as shown in page 4B To facilitate making the connections allow the cables to project by the required length for connection to the control board trans...

Страница 7: ...d supported on the pinion and with help of the level and clamping tool keep it horizontally leveled 4 Move the gate to manually back and forth to ensure that the gear rack is properly seated on the pi...

Страница 8: ...it counterclockwise until the engine moves the gate at idle The tuning must achieve a balance between the gate s irreversibility and the engine s power INSTALLING LIMIT SWITCH PLATE MAINTENANCE AND RE...

Страница 9: ...connecting the 4 motor wires to the appropriate inputs of the control board NOTE In this motor you must use two capacitors one of which works permanently and the other only works during the start up...