background image

Sliding Gate Opener

User Manual

PY300DCL

Website: www.gatexpertstore.com

E-mail: [email protected]

Содержание PY300DCL

Страница 1: ...Sliding Gate Opener User Manual PY300DCL Website www gatexpertstore com E mail sales gatexpertstore com...

Страница 2: ...eration When mounting and positioning this product please ensure the power cable is unplugged The motor cover will need to be removed to mount the motor to the mounting plate or directly to the concre...

Страница 3: ...eplace for free 4 The malfunction and damages caused by incorrect use or man fault is not covered by this warranty CONTACT US E mail sales gatexpertstore com Please fill in the order information in th...

Страница 4: ...ng Installing Motor Cover 7 Step 4 Motor Pad Footing 8 Step 5 Fitting Mounting Base and Motor 8 Step 6 Sprocket and Chain Motor Alignment 10 Step 7 Powering on 11 Step 8 Testing Travel and Limit Stops...

Страница 5: ...he opposite direction This will give you an understanding of the way how the opener moves the gate Figure 2 Note Ensure that the gate opener is unplugged before proceeding with installation Please kee...

Страница 6: ...injury to person or damage to property Instruct all users about the control systems provided and the manual opening operation in case of emergency Ensure that the power cable is connected to a RCD pr...

Страница 7: ...Picture Name Quantity 1 Motor 1 2 Manual Release Keys 2 3 Manual Release Bar 1 4 Remote Controls 2 5 Mounting Accessories Box 1 5 1 Sprocket Cover 1 5 2 Chain Including 2 Chain Links 6m 5 3 Tie Rod 2...

Страница 8: ...Picture Name Quantity 1 Infrared Photocell 1 2 Wireless Keypad 1 3 Alarm Lamp 1 Additional remote controls Spare Additional remotes for the automatic gate kit these will need to be paired to the motor...

Страница 9: ...ength of 12m Standard kit contains a 6m chain if the gate length is over 5 5m please consider to extend the length of the chain Gate motion is achieved by the rotating output sprocket of the gate open...

Страница 10: ...lide back and forth smoothly when moved by hand before installing the gate opener Wheels and guide rollers should rotate easily and be free from dirt or grime Track should be flat level and firmly aff...

Страница 11: ...the motor cover Remove the rubber grommet below the limit switch Figure 7 Figure 7 Sprocket cover installation as Figure 8 Figure 8 To make the motor into manual mode insert the key and open the manua...

Страница 12: ...urface is level and parallel to the driveway Mounting Base Dimensions Figure 9 Step 5 Fitting Mounting Base and Motor Fit anchor bolts included in kit or expansion bolts should be prepared by users ac...

Страница 13: ...sprocket and chain are correctly aligned Sprocket and chain should be centered as much as possible Take the motor away from mounting base Leave a space of 30cm from the motor to end of the chain Nut F...

Страница 14: ...tances should the gate opener output sprocket carry any weight of the gate It is the task of the gate castors or wheels to carry the weight of the gate If the gate doesn t slide freely by hand adjust...

Страница 15: ...pener make sure the gate can travel by hand in manual mode key unlocked Slide the gate to between the middle of the posts approximately see below diagrams Lock the manual release spanner key locked in...

Страница 16: ...g up the limit stop positions the sliding gate will automatically run to open limit stop positon and then to the closed limit stop postion do not cut off the power supply or stop the gate during it s...

Страница 17: ...minal J2 Terminal Transformer Secondary AC24V 3 3A Programming and Wiring Any works to the 110V 220V AC must only be performed by a licensed electrician Ensure power is off before any modifications ar...

Страница 18: ...MP Alarm Lamp 24VDC Terminal LAMP Alarm Lamp 24VDC J3 Terminal Terminal GND Common Terminal for Photocell Terminal PE Photocell Input N C Terminal 24 Additional Accessories 24VDC Additional accessorie...

Страница 19: ...erminal that you are looking to connect to Refer to Page 13 Tighten with a screwdriver to secure the wire in place Wiring to the Terminal Wiring to the Transformer Figure 18 Using a screwdriver to loo...

Страница 20: ...the digital will dispaly 2 4 Press and hold CLOSE until gate closes to a proper closed position The closed position will be determined by customer themselves 5 Press SET to confirm the closed position...

Страница 21: ...lowest level 3 Press SET to confirm the setting Note The sensivity should be set according to the gate weight to ensure the reverse function is workable or it may have potential safety concerns Figur...

Страница 22: ...ared Photocell is blocked the gate will stop and reverse immediately to protect user and property security To install photocells connect wiring as per Figure 23 The distance between photocell receiver...

Страница 23: ...gate will open 1m wide to allow pedestrian access Single Button Mode Remote Control Figure 24 Remote Control Learning 1 Press CODE button once the red light on digital tube will be on 2 Press the butt...

Страница 24: ...0 Clearing Remote Controls To delete all paired remote controls press and hold the button CODE till digital displays C all previously paired remote controls will be deleted Figure 26 Connecting Storag...

Страница 25: ...ar charger charger Storage Storage battery battery Control Control board board Figure 28 Maintenance The gate should be checked every month to make sure it operates normally For the sake of safety eac...

Страница 26: ...ared port and GND short circuit if connect infrared sensor please make sure the wiring is correct and the photocell is N C 3 Make sure that the photocell mounting position can be mutually aligned 4 Re...

Страница 27: ...Instructions for PY300DCL www gatexpertstore com 23 Drawing and Measurements Figure 27...