![Motorline professional MC61SE Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/motorline-professional/mc61se/mc61se_installer-and-user-manual_1838629009.webp)
8A
8B
8A
8B
CMD
SET
SEL
5s
CMD
SET
SEL
CMD
SET
SEL
CMD
SET
SEL
CMD
SET
SEL
5s
CMD
SET
SEL
CMD
SET
SEL
CMD
SET
SEL
EN
EN
EN
EN
• When this function is activated, the control board will only work if the service door isclosed.
If the door is open, the control board reject any opening or closing order.
0 - Disable | 1 - Enable
1 •
Press the
SEL
and
SET
buttons simultaneously
for 5 sec. to access the
programming menu.
4 •
The display will show the
value 0 or 1, which identifies
the option in which the
control board is currently
configured. Use the
SEL
button to put on the desired
option. Press the
SET
button
once to save this option.
2 •
The display will show
F
.
Press the
SEL
button as
many times as necessary
until the display shows
E
.
5 •
The display will show
E
and the configuration was
successful.
3 •
Press the
SET
button to
access the submenu.
6 •
To exit the programming
mode wait 10 sec. until (–)
appears.
For this function, you must have installed a safety device N.C at the door.
05. FUNCTIONS
ENABLE/DISABLE SERVICE DOOR
0-Disabled
• If you send an order to the gate completely open, it will close.
• If pressing during the closure, the gate reverses direction (it will open).
When disabled, you can control the opening or closing of the gate whenever you want, and their
behavior is: open-stop-close-stop-open-stop - (...) for each time you press a remote control key.
1 - Enabled
• This function makes the control board ignore all the orders sent by configured devices during the
course of opening and during the pause time.
• Pressing the remote control during the opening, the order is declined and the gate continues to open.
• When activated the condominium function is activated the closing time in 10 seconds.
1 •
Press the
SEL
and
SET
buttons simultaneously
for 5 sec. to access the
programming menu.
4 •
The display will show the
value 0 or 1, which identifies
the option in which the
control board is currently
configured. Use the
SEL
button to put on the desired
option. Press the
SET
button
once to save this option.
2 •
The display will show
F
.
Press the
SEL
button as
many times as necessary
until the display shows
L
.
5 •
The display will show
L
and the configuration was
successful.
3 •
Press the
SET
button to
access the submenu.
6 •
To exit the programming
mode wait 10 sec. until (–)
appears.
ENABLE/DISABLE CONDOMINIUM FUNCTION
05. FUNCTIONS