Electrical Installation :
If
you have purchased the
ELECTRIC DRIVE ACCELERATOR™ TOP WHEEL,
bring a cable from a
separate
MOTOR SOFT STARTER
unit to the
MOTOR CONNECTION BOX
(see Picture #24)
.
Then,
connect the motor cable to the
1.5 HP DRIVE MOTOR.
The motor has to be protected with an
OVERLOAD
RELAY WHICH NEEDS TO BE SET AT THE MOTOR-RATED FULL LOAD CURRENT FOR THE
PROPER VOLTAGE.
Connect
the air valve to an output from the car wash controller in series with the
N.O. AUXILIARY
CONTACTS
of the starter unit like shown on picture #24.
OUTPUTS 120VAC ONLY
CAR WASH CONTROLLER
NEUTRAL
Pic #24 Motor Starter Connections
NOTE:
ALWAYS CONNECT THE MOTOR TO A SOFT STARTING
DEVICE (SOFT STARTER OR VFD). NOT DOING SO WILL CAUSE SERIOUS
DAMAGES TO YOUR EQUIPMENT AND
VOID YOUR WARRANTY!
NOTE:
CONNECT THE AIR VALVE IN SERIES WITH
THE SOFT STARTER’S AUXILIARY CONTACTS.
NOT DOING SO MAY LEAD TO SERIOUS DAMAGE TO
YOUR EQUIPMENT IN THE EVENT THE MOTOR IS NOT
RUNNING WHEN THE BRUSH IS DOWN.
24 OR 120VAC
SOFT STARTER