![MOTKA MK-200 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/motka/mk-200/mk-200_user-manual_1837971010.webp)
10
2.1. Connecting the Power Supply
The MK-200 requires a +5 V operating voltage. An embedded regulator is
used to supply the internal +3.3 V digital power. The +5 V pins must be
connected to a +5 V power supply with external decoupling capacitors
(one 100 nF ceramic capacitor for each +5 V) as shown Figure 4. The
decoupling capacitors shall be placed close to the +5V pins whenever
possible for best performance.
Figure 4 – Power supply scheme
2.2. Connecting the Host
A host is required to drive the MK-200 through the UART interface with the
following configurations:
Baud rate:
115200 bps
Data bit:
8
Stop bit:
1
Parity bit:
None
Flow control: None
These configurations are not changeable.
The UART interface can be connected directly to another host processor
with a UART port (See Figure 5). If the MK-200 is to be connected to a
MK-200
+5V
Gnd
Gnd
+5V
100 nF
100 nF
Содержание MK-200
Страница 1: ...M MK K 2 20 00 0 U Us se er r s s M Ma an nu ua al l Revision 1 1 MOTKA LLP ...
Страница 4: ...4 List of Tables Table 1 MK 200 pin definitions 9 Table 2 Document revision history 26 ...
Страница 7: ...7 Related documents Command Reference MOTKA Motion Companion User s Manual ...
Страница 23: ...23 Figure 14 Recommended PCB footprint ...
Страница 27: ...27 ...