Introduction
LTC Manager is used to individually configure and calibrate the connected
LTC units. Configuration using LTC Manager is only necessary if installing
multiple LTC units or if changes to the default settings are required.
All LTC configuration and calibration operations are performed directly on an
LTC and configurations are not stored on disk.
Note:
LTC units come pre-configured to suit a single LTC or LTCD unit
installation using the initial factory sensor calibration.
The default CAN address for the LTC is hex 460.
The default CAN addresses for LTCD is hex 460 for Lambda sensor 1 and hex
461 for Lambda sensor 2.
Start LTC Configuration
•
Connect the unit to the PC (see
Appendix D – Wiring Details
)
•
Ensure the unit is powered
•
Start LTC Manager
o
Click the LTC Manager icon on the desktop
OR
o
Click Start > All Programs > MoTeC > LTC > LTC Manager.
•
Select the correct gateway and CAN bus (see
CAN Bus Interface
)
The main LTC Manager window displays the live configuration and status of all
LTC units present on the connected CAN bus.
Setup
CAN Address
The CAN setup determines which CAN address (specified in hex) the LTC
uses to transmit readings and diagnostic information. The format of the CAN
messages is described in.
Appendix E – LTC CAN Messages
Each LTC on a CAN bus must be configured with a unique CAN address.
See
Operation
for information on configuring a MoTeC Data Logger or ECU to
receive LTC CAN messages.