26
Operation
MoTeC 'Hundred Series' ECUs
MoTeC ‘Hundred Series’ ECUs (M400, M600, M800, M880) can be configured
to receive Lambda measurements from up to 12 LTCs using the existing PLM
CAN templates in the ECU Manager software. The M84 ECU can receive two
channels of Lambda with CAN addresses 460 and 461.
Received Lambda readings can be used in engine control and logged.
Refer to the ECU Manager software for more information.
Note:
The ECU only stores the Lambda readings from the LTC messages;
LTC diagnostic information is not stored.
Configure Hundred Series ECU Communications for LTC
•
Select Adjust > General Setup > Communication > CAN Setup
•
For single LTC configuration:
o
Select a spare CAN data slot in the range CAN 1 to CAN 6
o
Enter
1 -
PLM Receive for CAN Data
Enter the LTC CAN Address in decimal*. The address must match
the CAN address specified in LTC Manager.
•
For CAN Collect configuration:
The LTCs must be configured in LTC Manager for CAN Collect
functionality using address hex 460 for the CAN Collect Master.
o
Enter
1
- PLM Receive for CAN 6 Data
o
Enter the LTC CAN address in decimal* for CAN 6 address.
The address must match the CAN address specified in LTC
Manager for the CAN Collect Master LTC. The recommended
address is 1120.
* Important:
CAN addresses in ECU Manager are in decimal, while the CAN
addresses in LTC Manager are in hex. e.g. 1120 decimal = 460 hex
Configure M84 ECU Communications for LTC
•
Select Adjust > General Setup > Communication > CAN Setup
•
For single or dual LTC configuration:
o
Enter a CAN Address of 1120 (460 Hex) into the PLM CAN
Address
Assign Lambda measurements to a Hundred Series channel
Lambda measurements from the LTCs must be assigned to an ECU channel
before they can be used for engine control or logging.