Select one of the three options available:
o
Initial Factory Sensor Calibration
. This is the default value and
can be used in most cases.
o
Entered Free Air Calibration.
A calibration value from a previous
Free Air Calibration can be entered.
o
Free Air Calibration.
A calibration is performed with the sensor in
free air. To perform the free air calibration:
- Click Perform Air Calibration
Note:
The calibration process may take several minutes during
which the calibration progress window is displayed.
- The new calibration value is displayed. This value should be
recorded against the serial number of the sensor to enter this
calibration when the sensor is used with another LTC unit.
- To apply the new calibration click
OK.
•
Click
OK
to save the calibration method and settings to the LTC.
Tip:
Spare sensors can be air calibrated before an event and tagged with the
14 digit calibration number. This number can be used in the entered Free Air
Calibration option for quick replacement of a sensor during the event.