Motcom BeCOMS Скачать руководство пользователя страница 49

motcom

®

 BeCOMS

®

 

User Manual

Release 

220601

Page 6.7

6.7 BeCOMS

® 

Data_Logger measurement data storage and management      

      (optional)

BeCOMS

®

 Data_Logger is a PC program for displaying and storing the measured 

data.

For detailed information on Logger software please refer to the BeCOMS

® 

Data_ 

Logger user manual.

Data_Indicator software is used for reading and analysing the BeCOMS

®

 data files. 

For further information please refer to the BeCOMS

®

 Data_Indicator user manual.

The daily data files created by 

BeCOMS

®

 Data_Logger have an approximate size 

of 100MB per BeCOMS

®

 set. To save hard disk space, older files can be deleted, 

compressed and/or archived on CD. By compressing a daily log-file with WinRAR, 

WinZip or other suitable software, the size of the file can be reduced to approx. 

10MB.

WinRAR shareware is usually pre-installed on the monitoring PC.

i

i

Содержание BeCOMS

Страница 1: ...BeCOMS BCom Bearing Condition Monitoring UserManual Part No 1 900 00 00000 Release 220601...

Страница 2: ...s of Manufacturer motcom GmbH Kurt Schumacher Str 28 30 66130 Saarbr cken Germany Tel 49 0 681 8837904 0 Fax 49 0 681 8837904 19 Email info motcomgmbh com Internet www motcomgmbh com Version Chapter C...

Страница 3: ...ction Diagram 2 4 3 System Overview 3 1 3 1 Slip Ring Encoder SRE 3 2 3 2 Evaluator 3 3 3 3 Mechanical Adapter and Cable 3 5 3 4 Optional Data Logger PC with Data_Logger Software 3 8 4 Functional Desc...

Страница 4: ...gering 6 4 6 5 Alarm Resetting 6 6 6 6 Error Resetting 6 6 6 7 BeCOMS Data_Logger measurement data storage and management optional 6 7 6 8 Compressing Data Files 6 8 6 9 Capturing the Graphic Screens...

Страница 5: ...eCOMS User Manual Release 220601 Page v 10 Spare Parts 10 1 11 Connection Assembly Instructions 11 1 11 1 Connection Cable RS485 PCI Card to Evaluator 11 1 11 2 Assembly of the plug M23 11 4 12 Append...

Страница 6: ...motcom BeCOMS User Manual Release 220601 Page vi...

Страница 7: ...ll operating personnel has fully understood the contents of these operating instructions The Bearing Condition Monitoring System is sold under the names BeCOMS and BCom For simplification only BeCOMS...

Страница 8: ...anic or possess an equivalent level of training These notes contain important information and serve to ensure trouble free functionality These operating instructions may be used only by authorised per...

Страница 9: ...s EN 55011 2018 05 CISPR 11 2015 mod A1 2017 EN 55032 CISPR 22 EN 61000 4 2 EN 61000 4 3 EN 61000 4 4 EN 61000 4 5 EN 61000 4 6 EN 61000 4 8 66130 Saarbr cken Germany 2022 the 23th of February Dipl In...

Страница 10: ...isplay of all values It can transmit all data via RS485 interface to a computer running the BeCOMS Data_ Logger software optional for enhanced visualisation and data storage The Data_ Logger and motco...

Страница 11: ...to analysis tool for BeCOMS Logfiles User Manual incl CD with Software and instruction manuals Optional Data Logger PC or Notebook completely installed with Operating System Windows 10 64 Bit BeCOMS D...

Страница 12: ...n Description BeCOMS Bearing Condition Online Monitoring System Evaluator Control Device IPxx International Protection LED Light Emitting Diode LCD Liquid Cristal Display PC Personal Computer PCIe Per...

Страница 13: ...standardized industrial bidirectional communication Communication Protocol Modbus CAN Bus optional User interface LC Display 240 128 dots 1 LED red Shutdown 1 LED red Pre Alarm 1 LED green System Read...

Страница 14: ...mosignal in alarm level x x x Displays Thermosignal AC effective in alarm level x x x Displays Thermosignal DC effective in alarm level x x x Displays Thermosignal in mV x x x Triggers Pre Alarm using...

Страница 15: ...signal and mV thermosignal effective and engine speed in one y t graph x x Minimized polar diagram in the main window x Enlarged polar diagram in an own window incl integrated engine geometry for dama...

Страница 16: ...dev_motcom eagle block wiring bcom wiring03 sch Sheet 2 6 Fig 2 1 Basic principle The SRE sensor needs to be connected to the Evaluator connector 6 see Fig 2 1 Ports 1 3 are reserved for 24V power sup...

Страница 17: ...The Data_Logger and motcom Analysis software serves as an o ine analysis tool one Set of mechanical parts and cable for mounting the SRE at the engine consists of engine cover adapter disc intermedia...

Страница 18: ...nance It s highly rugged design ensures a trouble free operation under typical conditions refer to Chapter 2 General Technical Data and it s redundant thermovoltage read out satisfies even high securi...

Страница 19: ...ween 0 70 C and 0 80 relative humidity suitable for installation close to the engine It displays all measurement values and parameters and is used for diagnostics of the BeCOMS system The installation...

Страница 20: ...e wiped with a mild cleaning agent Please never use a solvent After installation and commissioning by service technicians approved by motcom GmbH the settings of the Evaluator should not be changed Th...

Страница 21: ...or made for each type of engine for an exemple see Fig 3 4 the individual parts must not be removed by untrained non motcom personnel Alignment errors cause high wear and tear and consequential damage...

Страница 22: ...e for a particular type of engine the individual parts must not be removed by untrained non motcom personnel Fig 3 5 shows an example of the adaptation with all the individual parts required Alignment...

Страница 23: ...adial shaft seal 03 Isolation washer 26 O ring 04 Engine seal 27 O ring 05 Cover 50 53 Cylinder screws 06 Adapter shaft 55 Cylinder screws 07 Cover seal 57 Centering sleeve 08 Isolation bush 59 Washer...

Страница 24: ...tware does not replace the interconnection of the Evaluator with the engine safety and alarm system To ensure proper functionality only motcom GmbH approved PC installations are supported to operate w...

Страница 25: ...ay per BeCOMS system supports Windows 7 8 1 and 10 Mouse Keyboard at least 3 free PCI PCIe slots Display resolution 1280 x 1024 or higher RS485 Interface RS2323 via optional converter depending on num...

Страница 26: ...motcom BeCOMS User Manual Release 220601 Page 3 10...

Страница 27: ...anges therein can hint to a potentially dangerous engine failure Dry friction R V Crankshaft Bearing Fig 4 1 Measurement principle in an engine This thermovoltage is typically low 1 mV during normal e...

Страница 28: ...with the firing sequence help to determine the location where the oil film ruptures see Fig 4 3 Fig 4 3 Thermovoltage signal course shown as screenshot of Data_Indicator Software The BeCOMS system is...

Страница 29: ...ble integration into alarm control systems motor management enhances security even further During start up shut down procedure BeCOMS will detect relatively large thermovoltage peaks compared to stead...

Страница 30: ...ncel the change of system value If Esc is pressed after entering the sublevel of menu items Setup Parameter or Setup CPU the Evaluator will restart Enter enter a sublevel or confirm a selected system...

Страница 31: ...C 1 1 AC Alarm percent 1 15 Setup CPU 2 LCD large font 2 2 Modbus enable 2 4 Modbus address 2 5 PIN for Setup 2 6 LCD brightness 2 1 Software Info 2 7 Test Features 3 Alarm Relay 3 2 Alm2 Pre Relay 3...

Страница 32: ...5 Graphic overview 4 5 1 BeCOMS graphical data indicator Menu level 1 Menu level 2 Menu level 3 Descriptions Measured values 2 Screenshot Shows further current BeCOMS measured values for the connecte...

Страница 33: ...he 0 channel of incremental encoder 0 or 1 4 7 Parameter setup Displays advanced system values 1 TS1 the value at the analog digital converter of the first thermovoltage measurement channel TS2 the va...

Страница 34: ...le 1 on page 4 9 To get write access to this parameter a PIN must be entered see Table 2 on page 4 11 Setup CPU View and change BeCOMS parameters If the sublevel was entered pressing Esc restarts the...

Страница 35: ...eed alarm in RPM Possible values 0 to 3000 step 50 The 0 value disables the alarm TS Alm Level1 AC The value of AC main alarm level in the RPM zone 1 Possible values 0 to 5 The 0 value disables the al...

Страница 36: ...buttons It is used during the impulse offset setup procedure as an indicator To start the procedure a PIN must be entered refer to Table 2 on page 4 11 PIN Impuls Offs PIN for impulse offset setup th...

Страница 37: ...ode Allows communication in both directions simultaneously Modbus enable Enable or disable values ON and OFF accordingly the Modbus interface Modbus address Modbus address in the range of 0 to 99 PIN...

Страница 38: ...d OFF Testsignal A Switch the test signal on channel A ON and OFF At the same time the values TS1 and TS2 are displayed signals from the first and the second thermovoltage measurement channels Testsig...

Страница 39: ...to the customer as part of the training for later reference During the initial installation the current BeCOMS wiring will be adapted to the existing alarm and monitoring system on site For further de...

Страница 40: ...installation and after each re installation The SRE must be synchronized with the engine crankshaft This procedure must be carried out during the initial installation as well as after each dismantlem...

Страница 41: ...unning a BeCOMS Advanced or BeCOMS Professional system The Data_Logger and Data _Indicator software comes pre installed with the supplied Data Logger PC The programmes must be configured correctly acc...

Страница 42: ...motcom BeCOMS User Manual Release 220601 Page 5 4...

Страница 43: ...ing as given in Chapter 12 Appendix see Fig 12 1 12 4 2 correct power supply on Evaluator 3 Evaluator display is on 4a correct power supply on RS 485 converter 5a green power light on see Fig 6 1 6a t...

Страница 44: ...onnel Turn engine to firing TDC of first cylinder number 1 at inline engine A1 at v type engine all valves must be closed Go to Table 1 page 4 10 IS Impuls Offset at the Evaluator menu Start Impuls Of...

Страница 45: ...al signals analyzes evaluates and displays them on its LC display These data including detected events are continuously made available through the RS485 interface to the installed PC with Data_Logger...

Страница 46: ...holds as alarm condition Thermosignal alarm levels are encoded as numbers from 1 to 5 the higher the number is the less sensitive is the system Over speed alarm level is given in RPM Alarm sensitivity...

Страница 47: ...electing the appropriate sensitivity level the operator defines up to which extend he would allow moving parts to be affected by friction With this information of fault on early stage the operator is...

Страница 48: ...Over speed Alarm triggered Over speed Alarm is not being reset automatically by the system either It must be reset by pressing the RESET button at the Evaluator for 3 seconds Attention Main Alarm can...

Страница 49: ...are is used for reading and analysing the BeCOMS data files For further information please refer to the BeCOMS Data_Indicator user manual The daily data files created by BeCOMS Data_Logger have an app...

Страница 50: ...data file which is to be compressed with the right button of the mouse A menu should pop up refer to Fig 6 2 2 Click on the option Add to Archive from the option list 3 Click OK refertoFig 6 3 andthe...

Страница 51: ...the data files may not be modified 1 Archive format RAR 2 Update mode Add and update files 3 Archiving option no tag selected 4 Compression method best 5 Volume size not limited 6 The original of the...

Страница 52: ...itoring application 3 Select the part of the diagram you want to save 4 Press the alt and Print Scrn button of the keyboard once 5 Then change back to MS Word so the YYYYMMDD_EngineXXX doc will be sho...

Страница 53: ...the keyboard hold it and move the mouse pointer to the last data files rar to be moved and c press the left button of the mouse once again and release the Shift button All the selected data files rar...

Страница 54: ...with this certain engine type the operator can identify the exact parts that cause the high thermosignal To get reliable failure localization results a continuous time interval should be analysed in...

Страница 55: ...earings with the lubrication oil film Test signals are visible among measurement data 2 on the stopped engine the crankshaft makes electrical contact with the bearing Test signals are not visible The...

Страница 56: ...motcom BeCOMS User Manual Release 220601 Page 7 2...

Страница 57: ...al computer needed for the software If a Not connected message appears in the event window after you have started Data_Logger the following steps may fix the problem in case the RS 485 converter is us...

Страница 58: ...nication problem with the Evaluator is depicted in Fig 8 2 below The operators should use the technical acceptable standards to trace the cause of the errors reported and skillfully fix the problem If...

Страница 59: ...the interface housing cover 2 Check whether the metal coupling inside is turning with the engine Warning Do not touch moving parts with tools or hands 3 If the coupling is broken it must be exchanged...

Страница 60: ...ring circuit e g grounding of the engine block generator is bad Wiring problems from the system itself the metal coupling can slip which leads to incorrect speed values Interference voltages or ground...

Страница 61: ...ncremental encoder not connected BeCOMS Error 32 BeCOMS test signal dead check all connections The error codes may be summed up For example error code 20 means that the error codes 04 and 16 appeared...

Страница 62: ...com BeCOMS User Manual Release 220601 Page 8 6 Single codes 32 16 8 4 Summed up codes 12 x x 20 x x 24 x x 28 x x x 36 x x 40 x x 44 x x x 48 x x 52 x x x 56 x x x 60 x x x x Table 8 1 Code combinatio...

Страница 63: ...be cleared easily by fault diagnostics on site In most cases a repair is not necessary Dismounting may only be performed on demand by motcom GmbH or its authorized service representatives Otherwise wa...

Страница 64: ...motcom BeCOMS User Manual Release 220601 Page 9 2...

Страница 65: ...used otherwise a proper working system could not be assured Picture Description Part No BeCOMS Slip Ring Encoder SRE 1 010 00 20000 BeCOMS Slip Ring Encoder SRE with throughout shaft 1 010 00 20011 Be...

Страница 66: ...e 220601 Page 10 2 Picture Description Part No 12 core communication cable 9 200 12 00000 Sub D9 connector 9 301 09 10000 6pol female connector 9 300 06 10000 12pol female connector 9 300 12 10000 12p...

Страница 67: ...Picture Description Part No RS485 converter PCI card for mounting inside PC 9 100 40 00000 RS485 converter PCI card for mounting inside PC 9 100 40 00010 RS485 converter PCIe card for mounting inside...

Страница 68: ...motcom BeCOMS User Manual Release 220601 Page 10 4...

Страница 69: ...outer insulation approx 23mm from the end of the cable Push back the braided shield Push the sealings over the wires Fig 11 1 Step 1 Sealing Coupling nut Connector housing Fig 11 2 Step 2a Sealing an...

Страница 70: ...over the wires Pull the enclosure cylinder over the soldered wires Finally seize the connector housing by using the installation wrench and a flat wrench No 22 For the correct assembling of the plug...

Страница 71: ...nector on the other side of the cable Fig 11 8 Below you ve got two pictures of the connector before and after assembly Fig 11 6 Step 5 Installation wrench Connector housing Flat wrench No 22 Fig 11 7...

Страница 72: ...n of wires approx 3 5mm from the end and twist them Solder green wire into pin No 5 on plug Solder blue wire into pin No 6 on plug Solder violet wire into pin No 7 on plug Solder grey wire into pin No...

Страница 73: ...motcom BeCOMS User Manual Release 220601 Page 12 1 12 Appendix 9 9 2015 5 47 12 PM f 0 65 Z Daten dev_motcom eagle block wiring bcom wiring03 sch Sheet 3 6 Fig 12 1 Cable connection...

Страница 74: ...motcom BeCOMS User Manual Release 220601 Page 12 2 9 9 2015 5 47 40 PM f 0 65 Z Daten dev_motcom eagle block wiring bco m wiring03 sch Sheet 4 6 Fig 12 2 Pin configuration 1 2...

Страница 75: ...motcom BeCOMS User Manual Release 220601 Page 12 3 9 9 2015 5 48 02 PM f 0 65 Z Daten dev_motcom eagle block wiring bcom wiring03 sch Sheet 5 6 Fig 12 3 Pin configuration 2 2...

Страница 76: ...COMS User Manual Release 220601 Page 12 4 9 9 2015 5 48 32 PM f 0 65 Z Daten dev_motcom eagle block wiring bcom wiring03 sch Sheet 6 6 Fig 12 4 Connectors and pin out of the BeCOMS Evaluator see also...

Страница 77: ...rm Relay COM RS485 SRE 5 6 2nd Alarm Relay NC RS485 SRE 6 7 Ready Relay NO RxD RS485 SRE 7 8 Ready Relay COM RxD RS485 SRE 8 9 Pre Alarm Relay COM GND SRE 9 10 Pre Alarm Relay NC GND SRE 10 11 Pre Ala...

Страница 78: ...motcom BeCOMS User Manual Release 220601 Page 12 6 Fig 12 6 Dimension Slip Ring Encoder SRE...

Страница 79: ...motcom BeCOMS User Manual Release 220601 Page 12 7 Fig 12 7 Dimension Slip Ring Encoder SRE with throughout shaft...

Страница 80: ...motcom BeCOMS User Manual Release 220601 Page 12 8 Fig 12 8 Dimensions Evaluator...

Страница 81: ...motcom BeCOMS User Manual Release 220601 Page 12 9...

Страница 82: ...mbH Kurt Schumacher Str 28 30 D 66130 Saarbr cken Phone 49 0 681 8837904 0 Fax 49 0 681 8837904 19 eMail info motcomgmbh com Internet www motcomgmbh com motcom BeCOMS User Manual en BeCOMS is a regist...

Отзывы: