motcom
®
BeCOMS
®
User Manual
Release
220601
Page 4.9
Table 1 Setup Parameter Details
TS Alm-Level DC
The value of DC main alarm level in the range of 0 to 5.
The higher the value, the less sensitive is the system.
The 0 value disables the DC alarm.
TS PreAlm-Level
The value of DC pre-alarm level in percents of DC main alarm.
Possible values: 40 to 100.
RPM Alarm-Level
The value of overspeed alarm in RPM.
Possible values: 0 to 3000, step 50.
The 0 value disables the alarm.
TS Alm-Level1 AC
The value of AC main alarm level in the RPM zone 1.
Possible values: 0 to 5.
The 0 value disables the alarm.
TS Alm-Level2 AC
The value of AC main alarm level in the RPM zone 2.
Possible values: 0 to 5.
The 0 value disables the alarm.
RPM for Level2
Engine rotation speed in RPM which defines the boundary between RPM
zone 1 and RPM zone 2.
Start Alminhibit
Time interval in seconds immediately after engine start during which the
main alarm is disabled.
Level 1
Level 2
Level 3
Descriptions
Содержание BeCOMS
Страница 1: ...BeCOMS BCom Bearing Condition Monitoring UserManual Part No 1 900 00 00000 Release 220601...
Страница 6: ...motcom BeCOMS User Manual Release 220601 Page vi...
Страница 26: ...motcom BeCOMS User Manual Release 220601 Page 3 10...
Страница 42: ...motcom BeCOMS User Manual Release 220601 Page 5 4...
Страница 56: ...motcom BeCOMS User Manual Release 220601 Page 7 2...
Страница 64: ...motcom BeCOMS User Manual Release 220601 Page 9 2...
Страница 68: ...motcom BeCOMS User Manual Release 220601 Page 10 4...
Страница 78: ...motcom BeCOMS User Manual Release 220601 Page 12 6 Fig 12 6 Dimension Slip Ring Encoder SRE...
Страница 80: ...motcom BeCOMS User Manual Release 220601 Page 12 8 Fig 12 8 Dimensions Evaluator...
Страница 81: ...motcom BeCOMS User Manual Release 220601 Page 12 9...