28
Part Number: 000016426 Rev 00 08/2020
OPERATIONAL CHECKS - PKU0155
SIPHON SYSTEM - PKU0155
To reduce mineral build-up and descaling frequency, the water in the sump trough must be
purged during each harvest cycle.
When the water pump de-energizes, the level in the water trough rises above the
standpipe, starting a siphon action. The siphon action stops when the water level in the
sump trough drops. When the siphon action stops, the float valve refills the water trough
to the correct level.
Follow steps 1 through 6 under water level check to verify the siphon system functions
correctly.
WATER LEVEL - PKU0155
Check the water level while the ice machine is in the ice mode and the water pump is
running. The correct water level is 1/4" (6.3 mm) to 3/8" (9.5 mm) below the top of the
standpipe. A line in the water trough indicates the correct level.
SIPHON CAP
SET THE WATER LEVEL TO THE
LINE IN THE WATER TROUGH
Содержание PKM0335
Страница 2: ......
Страница 6: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 10: ...THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 22: ...22 Part Number 000016426 Rev 00 08 2020 Installation Instructions Section 1 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 42: ...42 Part Number 000016426 Rev 00 08 2020 Cleaning and Sanitation Section 3 THIS PAGE INTENTIONALLY LEFT BLANK ...
Страница 54: ...CETTE PAGE LAISSÉE EN BLANC INTENTIONNELLEMENT ...
Страница 98: ...SE HA DEJADO ESTA PÁGINA EN BLANCO INTENCIONALMENTE ...
Страница 135: ......
Страница 136: ...Katom 305 Katom Drive Kodak Tennessee 37764 www customicemachines com motak Part Number 000016426 01 2021_Rev00 ...
Страница 137: ...Katom 305 Katom Drive Kodak Tennessee 37764 www customicemachines com motak Part Number 000016426 01 2021_Rev00 ...