Section 5: Module Configuration
5-19
Moseley SL9003Q
602-12016-01 Revision J
7) Use left or right arrow to select setting 0, 1 or 2
8) Press the <ENTER> button.
9) Press the <ESC> button twice
10) Use left or right arrow to select Yes to save settings
11) Press the <ENTER> button.
To set “Map Faults-Relays”, perform the following steps:
1) On the SL9003Q Tx Main Menu, use Up or Down arrow to select System
2) Press the <ENTER> button.
3) Scroll down to External I/O
4) Press the <ENTER> button.
5) Scroll down to Map Fault-Relays
6) Press the <ENTER> button.
7) Use left or right arrow to select Off or On for Map to Relays
8) Press the <ENTER> button.
9) Press the <ESC> button twice
10) Use left or right arrow to select Yes to save settings
11) Press the <ENTER> button.
In a Receiver
Relay 2: pins 5 (-) and 6 (+)
•
Any Fault or Alarm or Equipment Power Off: Relay 2 = Off (Set Open)
•
No Faults or Alarms and Equipment Power On: Relay 2 = On (Set Closed)
Relay 3: pins 3 (-) and 4 (+)
•
Receive RSL < -100dBm or Equipment Power Off: Relay 3 = Off (Set Open)
•
Receive RSL > -100dBm and Equipment Power On: Relay 3 = On (Set Closed)
Relay 4: pins 1 (-) and 2 (+)
•
Pre-BER > 1E-4 or Equipment Power Off: Relay 4 = Off (Set Open)
•
Pre-BER < 1E-4 and Equipment Power On: Relay 4 = On (Set Closed)
In a Transmitter
Relay 1: pins 7 (-) and 8 (+)
•
Tx control set OFF or transfer set COLD and unit is not Selected or Equipment Power Off:
Relay 1 = Off (Set Open)
•
Tx control set ON or AUTO or transfer set COLD and unit is selected and Equipment
Power On: Relay 1 = On (Set Closed)
Relay 2: pins 5 (-) and 6 (+)
•
Any Fault or Alarm or Equipment Power Off: Relay 2 = Off (Set Open)
•
No Faults or Alarms and Equipment Power On: Relay 2 = On (Set Closed)
Содержание Starlink SL9003Q
Страница 25: ...Section 2 Quick Start 2 9 Moseley SL9003Q 602 12016 01 Revision J Figure 2 4 Radio TX Status Performance Check ...
Страница 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Страница 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Страница 109: ...Appendix A Path Evaluation Information A 9 Moseley SL9003Q 602 12016 01 Revision J A 2 7 Path Calculation Balance Sheet ...
Страница 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Страница 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...
Страница 140: ...G 4 Appendix G Optimizing Radio Performance For Hostile Environments Moseley SL9003Q 602 12016 01 Revision J ...