Section 5: Module Configuration
5-9
Moseley SL9003Q
602-12016-01 Revision J
5.2.14 Decoder: S23 - SYSTEM CONFIG
R1/R2
: These switches select the Sample Rate Converter Data Source:
R1
R2
Sample Rate Converter Data Source
OFF OFF Compressed
OFF ON Linear
ON OFF Zeros
(Ground)
ON ON Sine
Generator
R3
: This switch selects the Trunk Compressed Input Clock: OFF=Normal (default),
ON=Inverted.
R4
: This switch selects the Trunk Linear Input Clock: OFF=Normal (default), ON=Inverted.
R5/R6
: These switches select 2-/4-Channel options:
R5 R6 2-/4-Channel
Select
OFF OFF 2-Channel
OFF ON Reserved
ON
OFF 4-Channel Master (1st Pair)
ON
ON
4-Channel Slave (2nd Pair)
R7
: This switch selects LEDs and Metering: OFF=Disabled/FP Select (default),
ON=Enabled/Forced On.
R8
: This switch selects Debug (B-Bus) options: OFF=Disabled (default), ON=Enabled.
5.2.15 Decoder: S32 SYSTEM CONFIG
M1/M2
: These switches select the Input Rate:
M1
M2
Input Rate (A/D & AES/EBU/SPDIF & SRC)
OFF OFF 44.1 kHz (Internal Oscillator)
OFF ON
48.0 kHz (Internal Oscillator)
ON
OFF 32.0 kHz (Internal Oscillator) Default
ON
ON
Linear Rate (M7, M8)
M3
: This switch selects the VCO Test Mode: OFF=Normal (External), ON=Test (Internal).
M4
: This switch selects the FIFO Data Source: OFF=Trunk, ON=Mux.
M5/M6
: These switches select the VCO Clock Source as shown in the following table:
M5
M6
VCO Clock Source
OFF OFF Trunk
Compressed
OFF ON Trunk
Linear
ON OFF Mux
Compressed
ON ON Mux
Linear
M7/M8
: These switches select the VCO Rate and Clock Frequency:
M7 M8 VCO
Rate
Clock
Frequency
OFF OFF 44.1K Hz
11.286 MHz
Содержание Starlink SL9003Q
Страница 25: ...Section 2 Quick Start 2 9 Moseley SL9003Q 602 12016 01 Revision J Figure 2 4 Radio TX Status Performance Check ...
Страница 86: ...5 22 Section 5 Module Configuration Moseley SL9003Q 602 12016 01 Revision J ...
Страница 90: ...6 4 Section 6 Customer Service Moseley SL9003Q 602 12016 01 Revision J ...
Страница 109: ...Appendix A Path Evaluation Information A 9 Moseley SL9003Q 602 12016 01 Revision J A 2 7 Path Calculation Balance Sheet ...
Страница 110: ...A 10 Appendix A Path Evaluation Information Moseley SL9003Q 602 12016 01 Revision J ...
Страница 118: ...D 2 Appendix D Microvolt dBm Watt Conversion 50 ohms Moseley SL9003Q 602 12016 01 Revision J ...
Страница 140: ...G 4 Appendix G Optimizing Radio Performance For Hostile Environments Moseley SL9003Q 602 12016 01 Revision J ...