SYMPTOM
POSSIBLE CAUSES
REMEDY
a) Faulty flywheel magnet
wínding
Check the resistance value of the fìywheel magnet winding after
disconnecting wires from terminals 5 and 6 of the terrninal strip.
The reading should be 2.6-2.8 ohms ± 10 % at room
temperature.
If not the coil must be replaced.
b) Faulty alternator
excitation winding
See 4.c
5. E
N
G
I
N
E
ACCELERATES BUT
DOES NOT WELD
c) Faulty condenser
See 2.c
d)Faulty printed circuit
board
See 2.d
e) Faulty welding diodes
See 2.e