background image

05/09/05 M43_EN

ENGLISH

ENGLISH

NOTE

By maintenance at care of the utilizer we intend all the operatios 

concerning the verification of mechanical parts, electrical parts 

and of the fluids subject to use or consumption during the normal 

operation of the machine.

For  what  concerns  the  fluids  we  must  consider  as  mainte

-

nance even the periodical change and or the refills eventually 

necessary.
Maintenance operations also include machine cleaning 

operations when carried out on a periodic basis outside of the 

normal work cycle.
The repairs 

cannot be considered

 among the maintenance 

activities, i.e. the replacement of parts subject to occasional 

damages and the replacement of electric and mechanic com-

ponents consumed in normal use, by the Assistance Authorized 

Center as well as by manufacturer.

The replacement of tires (for machines equipped with trolleys) 

must be considered as repair since it is not delivered as standard 

equipment any lifting system.

The periodic maintenance should be performed according to 

the schedule shown in the engine manual. An optional hour 

counter  (M)  is  available  to  simplify  the  determination  of  the 

working hours.

ENGINE AND ALTERNATOR
PLEASE REFER TO THE SPECIFIC MANUALS 

PROVIDED.

Every engine and alternator manufacturer has maintenance 

intervals and specific checks for each model: it is necessary 

to  consult  the  specific  engine  or  alternator  USER  AND 
MAINTENANCE manual.

VENTILATION

Make certain there are no obstructions (rags, leaves or other) 

in the air inlet and outlet openings on the machine, alternator 

and motor.

ELECTRICAL PANELS

Check condition of cables and connections daily.

Clean  periodically  using  a  vacuum  cleaner, 

DO NOT USE 

COMPRESSED AIR.

DECALS AND LABELS

All warning and decals should be checked once a year and 

replaced

 if missing or unreadable.

STRENUOUS OPERATING CONDITIONS

Under extreme operating conditions (frequent stops and starts, 

dusty environment, cold weather,extended  periods of no load 

operation, fuel with over  0.5% sulphur content) do maintenance 

more frequently.

BATTERY WITHOUT MAINTENANCE

DO NOT  OPEN THE BATTERY

The battery is charged automatically from the battery charger 

circuit suppplied with the engine.

Check the state of the battery from the colour of the warning 

light which is in the upper part.

- Green colour: battery OK

- Black colour: battery to be recharged

- White colour: battery to be replaced

NOTE

THE ENGINE  PROTECTION NOT WORK WHEN THE OIL 
IS OF LOW QUALITY BECAUSE NOT CHARGED REGU

-

LARLY AT INTERVALS AS PRESCRIBED IN THE OWNER’S 
ENGINE MANUAL.

IMPORTANT

In the maintenance operations avoid that pol

-

luting substances, liquids, exhausted oils, etc. 

bring damage to people or things or can cause 

negative effects to surroindings, health or safety 

respecting completely the laws and/or disposi-

tions in force in the place.

!

!

WARNING

 

Have 

qualified

 personnel do maintenance and troubleshooting work.

 

Stop the engine before doing any work inside the machine. If for any 

reason the machine must be operated while working inside, 

pay at-

tention

 moving parts, hot parts (exhaust manifold and muffler, etc.) 

electrical parts  which may be unprotected when the machine is open.

 

Remove guards only when necessary to perform maintenance, and 

replace them when the maintenance requiring their removal is complete.

 

Please wear the appropriate clothing and make use of the PPE (Per

-

sonal  Protective  Equipment),    according  to  the  type  of  intervention 

(protective gloves, insulated gloves, glasses).

 

Do not modify the components if not authorized.

    - See pag. M1.1 -

MOVING

PARTS

can injure

HOT surface

can

hurt you

!

M

43

MAINTENANCE

REV
.1-01/13

29

Содержание CD4R90119003

Страница 1: ...erador Stroomaggregaten Skupinagener toru CD4R90119003 Codice Code Code Codigo Kodezahl C digo Code K d Edizione Edition dition Edici n Ausgabe Edi o Editie Edice OPEN FRAME GE 10000 HZDM STAGE V GE 1...

Страница 2: ......

Страница 3: ...RT AND HANDLING M3 MACHINE UNPACKING PAG 12 M4 1 TRANSPORT AND HANDLING COVERED UNITS PAG 13 3 INSTALLATION AND USE M2 7 INSTALLATION PAG 14 M2 6 INSTALLATION ADVICES PAG 15 M20 SET UP FOR OPERATION D...

Страница 4: ...must also given to him Do not damage it do not take parts away do not tear pages and keep it in places protected from dampness and heat You must take into account that some figures contained in it wan...

Страница 5: ...22 Rated altitude above sea level 23 Max ambient temperature 24 Dry weight kg 25 Any additional information Any of our product is labelled with CE marking attesting its conformity to appliable direct...

Страница 6: ...amage can happen to persons or things HIGH VOLTAGE Attention High Voltage There can be parts in voltage dangerous to touch The non observance of the advice implies life danger FIRE Danger of flame or...

Страница 7: ...octor Suction of liquids from lungs If you suppose that vomit has entered the lungs as in case of spontaneous vomit take the subject to the hospital with the utmost urgency Inhalation In case of expos...

Страница 8: ...o di traino previsto Verificare il corretto assemblaggio della macchina al dispo sitivo di traino Verificare sempre che il gancio del veicolo sia adeguato al traino della massa totale del carrello Non...

Страница 9: ...ione causa un grave pericolo di ribaltamento o instabilit durante il funzionamento e durante la movimentazione con carrelli di traino In caso di necessit contattare il servizio di assistenza tecnica P...

Страница 10: ...lso eliminate sounds which would produce noise The unit has a protective closed frame which protects it against unintentional impacts during the handling and or transport the front panel is completely...

Страница 11: ...machine is necessary to record some data Please write the requested data inside the squares to side 1 Model of machine 2 Serial number of the machine 3 Serial number of the engine 4 Name of the deale...

Страница 12: ...ndling or taking away of parts contained inside the packing or in the set In case you find damages rough handling or absence of parts envelopes manuals etc we advise you to inform immediately our Tech...

Страница 13: ...and regulations Only authorized persons involved in the transport of the machine should be in the area of movement DO NOT LOAD OTHER PARTS WHICH CAN MODIFY WEIGHT AND BARICENTER POSITION IT IS STRICT...

Страница 14: ...05 12 19 CD4R9011_IT M 2 7 INSTALLAZIONE INSTALLATION INSTALLATION INSTALACI N LUFTZIRKULATION INSTALA O INSTALLATIE REV 1 03 20 M1 4 M1 4...

Страница 15: ...force ATTENTION All generating sets are equipped with a control system that is NOT influenced by standard environmental factors and is able to stop the unit in case of anomalous values in the fundamen...

Страница 16: ...tain pos sible liquid leakages hence no specific measures are needed in this regard In case of doubts concerning your genset do not hesita te to contact our technical sales office ATTENTION Engine and...

Страница 17: ...to it by using screw anchors or rag bolts Base dimensions should exceed genset dimensions of at least 200 mm on each side Base should weigh three times static genset weight indicated on the technical...

Страница 18: ...e evaluated If the duct is not appro priately insulated room temperature may increase considera bly for this reason it may be necessary to install an electro ventilator for correct air exchange a Radi...

Страница 19: ...il filling and level ispections must be carried out with the engine on a flat surface 1 Remove oil filler cap 24 2 Pour the oil in and reassemble oil cap 3 Check the oil level using the dipstick 23 th...

Страница 20: ...by means of the GFI Connect the generating set to an earthing system via a cable certain efficiency using the ground terminal 12 on the machine Earthing WITH GROUND FAULT INTERRUPTER The grounding co...

Страница 21: ...t low temperatures The motor will normally start up without problems down to temperatures of 10 C For start up and use at lower temperatures please see the engine manual or turn to our Technical Assis...

Страница 22: ...e sockets 15 A C socket AUX sockets for load connection 12 Earth terminal Ground connection point for gen set Z6 Digital multifunction meter GE voltage VAC GE Hz Frequency Total hour counter Resettabl...

Страница 23: ...8528 1 and 3046 1 Norms and their definitions are listed in the manual s TECHNICAL SPECIFICATIONS page During the use of the electricity generating group NEVER EXCEED the power indications paying car...

Страница 24: ...ating machine coupled to the motor allows it see to a start up with reduced voltage star point triangle start up or with autotransformer or use a soft start system In all cases when the user circuit r...

Страница 25: ...lectricity generating group in combination with the EAS automatic start up panel forms a unit for distributing electrical energy within a few seconds of a power failure from the commercial electrical...

Страница 26: ...er clogged 2 Overload 3 Injectors defective Injection pump requires calibra tion 1 Clean or replace 2 Check the load connected and diminish 3 Ask for intervention of Service Department White smoke 1 O...

Страница 27: ...ith setting wrong or fault 1 Regulate speed to its nominal no load value 2 Check winding diodes etc on alternator See to alternator manual Repair or replace A s k f o r intervention of Service Departm...

Страница 28: ...ALS AND LABELS All warning and decals should be checked once a year and replaced if missing or unreadable STRENUOUS OPERATING CONDITIONS Under extreme operating conditions frequent stops and starts du...

Страница 29: ...uested number of hours has not been attained EVERY WEEK EVERY MONTH AND OR AFTER INTERVENTION ON LOAD EVERY YEAR 1 TEST orAUTOMATIC TEST cycle to keep the generating set constantly operative NO LOAD X...

Страница 30: ...d or dispositions in force in the place M 45 STORAGE and disassEmble REV 0 06 00 DISASSEMBLE Have qualified personnel disassemble the machine and dispose of the parts including the oil fuel etc in a c...

Страница 31: ...urs limited at 500 h No overload is admitted Prime power PRP maximum available power for use at variable loads for a yearly illimited number of hours The average power to be taken during a period of 2...

Страница 32: ...05 12 19 CD4R9011_IT M 2 7 1 DIMENSIONI DIMENSIONS DIMENSIONS DIMENSIONES ABMESSUNGEN DIMENS ES AFMETINGEN REV 1 03 20 610 665 715 1005 210 840 925 425 1430 645...

Страница 33: ...11 01 01 Note NOTE 34...

Страница 34: ...11 01 01 Note NOTE 34...

Страница 35: ......

Страница 36: ...MOSA div della BCS S p A Viale Europa 59 20090 Cusago Milano Italy Tel 39 0290352 1 Fax 39 0290390466 www mosa it...

Отзывы: