COMANDI - CONTROLS - COMMANDES - MANDOS - BEDIENELEMENTE - COMANDOS
СИСТЕМЫ УПРАВЛЕНИЯ - BEDIENING
Pos.
Description
Function
Z2
Thermal-magnetic circuit breaker
General switch for the gen-set.
It protects both gen-set and related electrical circuit from over current /short circuit.
D
Ground fault interrupter (30 mA)
Device for protection against not-direct contacts for TN and TT systems (neutral grounded
to frame)
59B
AUX thermal circuit breaker
Overcurrent protection of the equipments connected to the single-phase sockets
15
A.C. socket
AUX sockets for load connection.
12
Earth terminal
Ground connection point for gen-set.
Z6
Digital multifunction meter
GE voltage VAC - GE Hz Frequency - Total hour counter - Resettable split
time hour counter (for maintenance) - Battery voltage VDC
Q1
Starter key
Starting and stopping key of the generating set.
O1
Oil pressure warning light
Indicates engine stop due to low oil pressure.
F5
Warning light, high temperature
Indicates engine stop due to high temperature of the engine.
N1
Battery charger light
Signals a fault in the motor battery charging circuit.
Z6
N1
Q1
F5
59B
15
12
15
Z2-D
O1
Z2
D
CEE version
REV
.1-09/19
GE 10000 KD - GE 10000 HZDM 230Vx3
GE 12000 KD - GE 12000 HZDT 400V/230Vx2