14
INSTALLATION
Caution!
On completion of the cooker installa-
tion, the tightness of all connections
should be checked, e.g. applying
water with soap.
Do not use fire to check tightness.
Important!
Each time you replace a reducer
carry out technical inspection of the
cooker that covers gas valves and
proper operation of the flame failure
cut-off device.
The cooker has threaded 1/2” pipe connec-
tor.
The connector must be screwed in with a dy-
namometric spanner with a maximum torque
of 20 Nm. It is recommended to seal connec-
tions with a teflon sealing tape. If the torque
is too high or tow is used, the connection be
damaged and become leaky.
When connecting the cooker to the gas sup-
ply, a metal tip of at least 0.5 m length with
an end for a 8x1 mm hose should be screwed
onto the R1/2” terminal. In order to screw the
tip in, you should unscrew the spring of the
cover hinge. The gas hose should not touch
metal elements of the cooker back shield.
Caution!
The cooker may only be connected
to a liquid gas cylinder or the existing
gas supply by an authorised fitter,
observing all safety rules.