Morningstar SureSine 1000 Скачать руководство пользователя страница 7

MS-003650

MORNINGSTAR

World’s Leading Solar

 Controllers 

&

 Inver ters

i

Table of Contents

1.0 Introduction 

................................................................................................................1

1.1 Features 

.................................................................................................................1

1.2 

Components of the 150 W & 300 W Models ........................................................2

1.3 

Components of the 700 W Models .......................................................................3

1.4 

Components of the 1,000 W to 2,500 W Models .................................................4

1.5 

Dimensions of the 150 W & 300 W Models ..........................................................5

1.6 

Dimensions of the 700 W to 2,500 W Models .......................................................6

2.0 Installation 

..................................................................................................................7

2.1 Required 

Tools 

.......................................................................................................7

2.2 

Additional Hardware Requirements .......................................................................7

2.3 Mounting 

...............................................................................................................8

2.3.1 

Safety Considerations for Mounting .........................................................9

2.3.2 Mounting 

Procedure 

...............................................................................10

2.4 Adjusting 

Settings 

...............................................................................................11

2.4.1 

DIP Switch Location ................................................................................11

2.4.2 

DIP Switch Confi guration Options ..........................................................12

2.5 

Remote Switch Installation (Optional) .................................................................13

2.6 

Auxiliary Power (Optional) ...................................................................................14

2.7 Inverter 

Wiring 

.....................................................................................................15

2.7.1 

Terminal Torque Requirements  ..............................................................15

2.7.2 

Over-current Protection Requirements ...................................................16

2.7.3 

DC and AC Conductor Sizing Requirements ..........................................17

2.7.4 

Grounding and Bonding Requirements ..................................................18

2.7.5 Grounding 

Connections 

.........................................................................20

2.7.6 DC 

Connections 

.....................................................................................22

2.7.7 AC 

Connections 

......................................................................................26

2.7.8 AC 

Wiring 

...............................................................................................27

2.8 

Check Wiring and Power Up  ..............................................................................28

3.0 Operation 

.................................................................................................................29

3.1 LED 

Indications 

....................................................................................................29

3.2 

AC Output Mode Switch Operation ....................................................................29

4.0 Communication 

Options 

...........................................................................................30

4.1 Bluetooth 

.............................................................................................................31

4.1.1 

To Connect the SureSine using Bluetooth ..............................................31

4.1.2 

SureSine Utility App ................................................................................32

4.2 

Ethernet (for Modbus™ TCP/IP) ..........................................................................33
4.2.1 

To Connect to the Internet using Modbus Protocols .............................33

4.3 

EIA-485 Device Communication .........................................................................34
4.3.1 

To Connect the SureSine Inverter to an EIA-485 Device ........................34

4.4 USB 

Port 

..............................................................................................................36

4.4.1 

To Connect to the USB Port....................................................................36

4.5 

MS-CAN (Future Feature) ....................................................................................37
4.5.1 

To Connect the SureSine to another Morningstar Device ......................37

4.5.2 

To Connect the SureSine to a Morningstar Network ..............................38

5.0 

Firmware Update Procedure ....................................................................................38

6.0 Specifi cations ............................................................................................................39

Appendix A: 

Conductor Sizing ..........................................................................................44

A.1 

Stranded Copper Wire Rated for 75°C ................................................................44

A.2 

Solid Copper Wire Rated for 75°C ......................................................................45

A.3 

Stranded Copper Wire Rated for 90°C ................................................................46

Содержание SureSine 1000

Страница 1: ...lation and Operations Manual 150 W 300 W 700 W 12 V 24 V 48 V Models 1 000 W 1 250 W 24 V 48 V Models 2 500 W 48 V Only Models September 2022 Rev B08 MORNINGSTAR World s Leading Solar Controllers Inve...

Страница 2: ...ontained in this document are veri ed to be as accurate as possible at the time of publication However because Morningstar Corporation s products and their performance are constantly evolving Mornings...

Страница 3: ...performing this task Failure to observe this notice could result in personal injury or equipment damage NOTE Indicates a procedure or function that is important to the safe and proper operation of the...

Страница 4: ...f installation WARNING FIRE HAZARD A risk of re may exist if a 120 Vac power source is wired incorrectly to 120 240 Vac panel containing multi wire branch circuits MOUNTING CLEARANCE AND LOCATION SAFE...

Страница 5: ...erminals Determine if battery is inadvertently grounded If so remove the source of contact with ground Contact with any part of a grounded battery can result in electrical shock The likelihood of such...

Страница 6: ...g Do not attempt to charge a frozen battery Ensure that the charging equipment implemented in the system meets the charging requirements for the battery bank and varied charging The SureSine Low Volta...

Страница 7: ...Sizing Requirements 17 2 7 4 Grounding and Bonding Requirements 18 2 7 5 Grounding Connections 20 2 7 6 DC Connections 22 2 7 7 AC Connections 26 2 7 8 AC Wiring 27 2 8 Check Wiring and Power Up 28 3...

Страница 8: ...ure 15 Internal Grounded Neutral vs External Grounded Neutral Internal Neutral Ground Bond removed 19 Figure 16 DC Connections on 150 W 300 W Models with Negative Grounding 24 Figure 17 DC Connections...

Страница 9: ...volt DC systems dependent on model purchased Extensive electronic protections ensure protection against faults and user mistakes such as short circuits overloads high temperatures and low voltage disc...

Страница 10: ...2 MS 003650 Rev B08 INTRODUCTION 1 2 Components of the 150 W 300 W Models Figure 2 shows the components included with the 150 and 300 W models Figure 2 SureSine Inverter Features 150 W 300 W Models...

Страница 11: ...3 INTRODUCTION MS 003650 Rev B08 1 3 Components of the 700 W Models Figure 3 shows the components included with the 700 W models Figure 3 SureSine Inverter Features 700 W Models...

Страница 12: ...650 Rev B08 INTRODUCTION 1 4 Components of the 1 000 W to 2 500 W Models Figure 4 shows the components included with the 1 000 W to 2 500 W models Figure 4 SureSine Inverter Features 1 000 W to 2 500...

Страница 13: ...5 INTRODUCTION MS 003650 Rev B08 1 5 Dimensions of the 150 W 300 W Models Figure 5 Dimensions 150 W to 300 W Models...

Страница 14: ...6 MS 003650 Rev B08 INTRODUCTION 1 6 Dimensions of the 700 W to 2 500 W Models Figure 6 Dimensions 700 W to 2 500 W Models...

Страница 15: ...rimping Tool Wrench 2 2 Additional Hardware Requirements Depending on the type of installation additional hardware may be required This hardware is NOT provided with the SureSine Inverter These types...

Страница 16: ...wall the inverter can be mounted either portrait style or landscape style Ensure that there is enough space inside the enclosure for the wiring and ventilation For optimal ventilation and cooling mou...

Страница 17: ...mpartment Overheating may result Ensure adequate space around the components to ensure suf cient ventilation around the equipment Locate the SureSine on a surface that is protected from direct sun hig...

Страница 18: ...res or other objects located on the opposite side of the surface Ensure the surface is strong enough to support the weight of the inverter and anything else mounted on it It may require additional sup...

Страница 19: ...ers for the inverter Each switch has an ON OFF position See Section 2 4 2 on page 12 for details on speci c settings IMPORTANT Check that the DIP Switches are properly con gured for the designed insta...

Страница 20: ...ough RS485 communication port or Bluetooth App ON PRESETS LVD is set with the 5 DIP Switch values and cannot be modi ed 5 Low Voltage Disconnect PRESETS I E Default For 12 V 24 V or 48 V Systems OFF A...

Страница 21: ...Figure 22 on page 29 If the site application requires a Remote ON OFF Switch the following illustration shows where to connect the wires Note Closed ON and Open OFF Remote Switches vary widely by manu...

Страница 22: ...ional Auxiliary Power for 1 W Maximum 12 Vdc applications is available on the 700 W to 2 500 W Models only These types of applications include EIA 485 Communication Bus Small DC devices e g LEDs Figur...

Страница 23: ...l with any AC power sources The SureSine inverter is not capable of synchronizing AC output phases AC power from utility generator and inverter AC power can feed back into the unit and instantly damag...

Страница 24: ...mage the equipment Fuses single pole circuit breakers or single pole disconnect switches must only be installed on ungrounded system conductors It is acceptable to use double pole breakers or double p...

Страница 25: ...how the minimum sizing requirements for 75 C wire allowed by U S National Electrical Code of each SureSine model when operated at the maximum continuous current rating of the inverter Conductors rated...

Страница 26: ...ound bond AC neutral ground bond and a chassis ground connection The DC input is isolated from the AC output and chassis so the inverter can have a positive or negative DC system ground depending on t...

Страница 27: ...ground bond Do NOT remove the neutral ground bond without having a permanent external neutral ground bond This can only be performed by quali ed personnel and requires tool access to the interior of t...

Страница 28: ...cle or ship metal frame and grid shore power is bonded to the shore earth ground With both neutral and line isolated from the other AC source with a double pole transfer switch the SureSine inverter c...

Страница 29: ...ent from the bus bar to ground is sized to the highest over current protection rating of the DC System 2 7 5 2 DC System Ground Ensure that the DC system ground is properly bonded to ground NEC Sectio...

Страница 30: ...Be certain that the battery connection is made with correct polarity The SureSine has battery reverse polarity protection implemented with an internal fuse which will have to be replaced if connected...

Страница 31: ...ct a battery cable between the grounded battery bank post for a negative grounded system or for a positive grounded system and inverter battery terminal of the same polarity STEP 3 Connect a battery c...

Страница 32: ...24 MS 003650 Rev B08 INSTALLATION Figure 16 DC Connections on 150 W 300 W Models with Negative Grounding Figure 17 DC Connections on 150 W 300 W Models with Positive Grounding...

Страница 33: ...25 INSTALLATION MS 003650 Rev B08 Figure 18 DC Connections on 700 W to 2 500 W Models with Negative Grounding Figure 19 DC Connections on 700 W to 2 500 W Models with Positive Grounding...

Страница 34: ...e manufacturer does not provide a surge rating for the load check with the manufacturer or multiply the maximum power by an appropriate sizing factor for the type of load being used If there are other...

Страница 35: ...ral ground bond has been removed Refer to Section 2 7 4 1 for details A three conductor copper cable with at least a 75 C insulation rating can be used for wiring the AC circuits 2 7 8 1 AC Wiring Pro...

Страница 36: ...e battery to the SureSine with the breaker or disconnect closed will cause a spark at the point of connection There is a RISK OF EXPLOSION in hazardous areas or locations where explosive gases have ac...

Страница 37: ...INK GREEN Low Voltage Disconnect LVD Warning RED GREEN Low Voltage Disconnect LVD RED not blinking RED Inverter or System Fault Critical Fault Requires a reboot OFF not blinking RED Inverter or System...

Страница 38: ...ment Future Feature Improvement MS CAN Morningstar Communication Area Network for a wired communication connection to other Morningstar products 700 W to 2 500 W Models Bluetooth for wireless communic...

Страница 39: ...enabling this feature 4 1 1 To Connect the SureSine using Bluetooth 1 Set the AC Output Mode Switch to REMOTE 2 Make sure the Bluetooth feature on your digital device is turned ON 3 See Section 4 1 2...

Страница 40: ...itoring and settings adjustments This app is designed for Android and Apple devices and connects using Bluetooth The SureSine Utility App is available at Google Play and Apple App stores Download and...

Страница 41: ...ister locations scaling and variable de nitions Use a CAT5 CAT6 or CAT7 cable with an RJ 45 plug for connections 4 2 1 To Connect to the Internet using Modbus Protocols 1 Insert one end of a CAT5 CAT6...

Страница 42: ...rnal 12 V power source to enable the EIA 485 communications The 12 Vdc Auxiliary Power feature of 700 W to 2 500 W models can be used therefore to power Morningstar EIA 485 devices in an EIA 485 Netwo...

Страница 43: ...nd GND terminal wire from the EIA 485 device s to the 12 V terminal of the SureSine inverter connect the Power terminal wire from the EIA 485 device s to the 12 V terminal of the SureSine inverter Not...

Страница 44: ...e for rmware updating This port requires a USB A plug This feature works with the following USB devices USB ash drive External hard drive Figure 30 USB Port Locations 4 4 1 To Connect to the USB Port...

Страница 45: ...or updates Note The Morningstar component must be MS CAN enabled 4 5 1 To Connect the SureSine to another Morningstar Device 1 Insert one end of an RJ 45 cable CAT5 CAT6 or CAT6e into the MS CAN IN po...

Страница 46: ...able into the MS CAN IN port on the next Morningstar device in the network 5 Insert a 120 Ohm CANBUS terminator resister into the MS CAN OUT port on the nal device if no other Morningstar devices are...

Страница 47: ...l convection Fanless natural convection Operating Temperature Range TBD 50 C TBD 50 C Storage Temperature Range Operational Humidity Level 100 RH non condensing 100 RH non condensing Peak Ef ciency 92...

Страница 48: ...S CAN Wireless Communications Bluetooth Bluetooth Wireless App Android or Apple Android or Apple Data Storage 4 MB 5 years internal 4 MB 5 years internal UL Certi cations UL 1471 UL 458 UL 62368 UL 14...

Страница 49: ...C Short Circuit AC Overload High Low Voltage Battery Reverse Polarity Replaceable internal fuse Replaceable internal fuse AC Output Protection Against Short Circuit Yes Yes AC Output Protection Agains...

Страница 50: ...e Range 10 5 to 16 5 V 21 0 to 33 0 V 42 0 to 66 0 V 10 5 to 16 5 V 21 0 to 33 0 V 42 0 to 66 0 V Maximum Continuous DC Input Current Maximum Continuous AC Input Current Maximum DC Input Voltage witho...

Страница 51: ...ht kg 13 3 kg 22 1 kg Shipping Weight Dimensions L W H 20 3 x 9 7 x 6 1 524 mm x 247 mm x 96 mm 21 7 x 9 7 x 6 1 551 mm x 247 mm x 156 mm IP Rating IP 20 IP 20 Terminal Types See Table 2 on page 15 fo...

Страница 52: ...0 49 27 32 50 5 41 5 91 6 50 7 22 8 12 9 28 10 83 12 99 16 24 21 65 35 3 40 3 71 4 08 4 54 5 11 5 84 6 81 8 17 10 21 13 62 25 2 14 2 34 2 57 2 86 3 22 3 68 4 29 5 15 6 43 8 58 16 1 35 1 47 1 61 1 79 2...

Страница 53: ...07 5 63 6 34 7 24 8 45 10 14 12 68 16 90 25 2 66 2 90 3 19 3 54 3 99 4 56 5 32 6 38 7 97 10 63 16 1 67 1 82 2 01 2 23 2 51 2 87 3 34 4 01 5 01 6 69 10 1 05 1 15 1 26 1 40 1 58 1 80 2 10 2 52 3 15 4 21...

Страница 54: ...8 4 54 5 11 5 84 6 81 8 17 10 21 13 62 25 2 14 2 34 2 57 2 86 3 22 3 68 4 29 5 15 6 43 8 58 16 1 35 1 47 1 61 1 79 2 02 2 31 2 69 3 23 4 04 5 38 10 0 85 0 93 1 02 1 13 1 27 1 46 1 70 2 04 2 55 3 40 6...

Страница 55: ...7 5 63 6 34 7 24 8 45 10 14 12 68 16 90 25 2 66 2 90 3 19 3 54 3 99 4 56 5 32 6 38 7 97 10 63 16 1 67 1 82 2 01 2 23 2 51 2 87 3 34 4 01 5 01 6 69 10 1 05 1 15 1 26 1 40 1 58 1 80 2 10 2 52 3 15 4 21...

Страница 56: ...ior to return of any unit s under this warranty Required RMA information A purchase location business or company name and date B full model and serial numbers SN is 8 digits on unit bar label C failur...

Страница 57: ...TIES INCLUDING WITHOUT LIMITATION WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE No Morningstar distributor agent or employee is authorized to make any modi cation or extension to...

Страница 58: ...22 150 W 300 W Models Negative Grounding 24 Positive Grounding 24 700 W to 2 5 kW Models Negative Grounding 25 Positive Grounding 25 DC Ground Bond 18 DC System Ground 21 DC Voltage Requirements 7 DC...

Страница 59: ...autions C Notes C Warnings C Safety Information C Settings 11 Speci cations 1 25 kW 2 5 kW Models 42 150 W 300 W 39 700 W 1 kW Models 40 Status LED 28 29 SureSine Utility App 31 32 36 T TCP IP 33 Term...

Страница 60: ...52 MS 003650 Rev B08 Index Notes...

Страница 61: ...MORNINGSTAR World s Leading Solar Controllers Inverters MS 003650 Rev B08 2022 Morningstar Corporation All rights reserved...

Отзывы: