29
OPERATION
MS-003650
(Rev B08)
3.0 OPERATION
3.1 LED
Indications
Two Light Emitting Diodes (LEDs) are on the front of the unit to provide Status and AC
Output Status. Table 8 defi nes what the LEDs represent.
Table 8: LED Indications
AC Output LED
STATUS LED
Operation or State
OFF
OFF
No power or Battery below 9.5 V
OFF
GREEN
AC Output OFF
GREEN
GREEN
AC Output ON
GREEN (BLINK)*
GREEN
AC Standby Mode
RED (BLINK)*
GREEN
Low Voltage Disconnect (LVD) Warning
RED
GREEN
Low Voltage Disconnect (LVD)
RED
(not blinking)
RED
Inverter or System Fault *
(Critical Fault. Requires a reboot.)
OFF
(not blinking)
RED
Inverter or System Fault *
*0.5 Hz rate.
3.2 AC Output Mode Switch Operation
The AC Output Mode Switch will always turn the inverter on directly in the ON (up)
position. To enable ON/OFF control with a wired remote switch or a communication
command (digital command), the switch must be in the REMOTE position. Select
remote switch or digital command using DIP Switch # 1.
Figure 22: AC Output Mode Operation and Bluetooth Activation