38
MS-003650
(Rev B08)
FIRMWARE UPDATE PROCEDURE
4.5.2
To Connect the SureSine to a Morningstar Network
1. Insert one end of an RJ-45 cable (CAT5, CAT6, or CAT6e) into the
MS-CAN OUT
port on the fi rst device in the daisy chain.
2. Insert the other end of that RJ-45 cable into the
MS-CAN IN
port on the
SureSine Inverter.
3. Insert another RJ-45 cable into the
MS-CAN OUT
port on the
SureSine Inverter.
4. Insert the other end of the RJ-45 cable into the
MS-CAN IN
port on the
next Morningstar device in the network.
5. Insert a 120 Ohm CANBUS terminator resister into the
MS-CAN OUT
port on the fi nal device, if no other Morningstar devices are to be
connected.
Figure 32: Communication Using MS-CAN with Multiple Devices
5.0
FIRMWARE UPDATE PROCEDURE
To update the SureSine fi rmware, perform the following procedure.
6. Go go to
www.morningstarcorp/support
and copy the fi rmware update program
to a USB data storage device (such as a fl ash drive).
7. Insert a USB-A plug for a USB data storage device into the USB data port.
8. Use the SureSine Utility App to activate the fi rmware update.
Содержание SureSine 1000