Operator Manual
Digibook 300
31
rev. 3.00
10.1
FUNDAMENTALS
Pay Attention during the glue
loading because of the high
temperature, as indicated by
the label, and use protective
systems such as gloves.
Never open the tank when it
is cold.
The moisture in the air would enter
the tank and remain trapped, causing
premature aging (curing) of the PUR
glue and producing blockages and
maintenance need.
The machine can’t stay with
the glue tank opened more
than 10 minutes if there is
PUR glue inside.
The glue in contact with moist air
modifies her composition, creating
damages to the machine.
The machine can’t stay with
the glue system empty for
more than 2 minutes
The PUR glue dries permanently; in
this case you risk permanent damage
to the glue system. If you don’t have
a glue cartridge available, put in the
tank at least 500 grams of Blue and
wait to be melted before to switch
off the machine.
The tank has to be added
with the same type and mod-
el of glue. You can use a dif-
ferent kind of glue only when
the system is completely
empty and cleaned by using
the Blue-Cleaner.
Drain as much as possible the glue
that you want to replace.
Enter in the tank a quantity of about
600g of Blue-Cleaner and make it
protrude from the main slot and the
channel of the glue; if at the end of
this cleaning cycle you are not sure
that from the valve 100% Blue-
Cleaner exits, repeat the operation.
Avoid opening the lid fre-
quently, the moisture in the
air damages the features and
durability of the glue.