Description of functioning
t e c h n i c a l
23
3.2- Troubleshooting
A.S.S. Control
It’s an appliance connected to BMF net from the main control board of the boiler, it’s
used by the A.S.S. (After Sales Service) to confi gure and adjust the boiler parame-
ters.
To enter in the different menus, the ON/OFF, WINTER and COMFORT push buttons
must be used.
- ON/OFF ===> Shows boiler status.
- WINTER ===> Adjust boiler parameters (AUTOTEST)
- Comfort ===> Confi gure the boiler.
Showing boiler status
.
The symbols from the top of the display show the actual state of the different
inputs/outputs and with both 7 segment displays show set points, temperatures,
water fl ow, pressure and power of the boiler.
The values of visualization are shown in groups of two and using the push buttons
to increase/decrease D.H.W. set point a
l
l the different groups will be shown
19
B = PUMP
V = FAN
C = SPARK
G = GAS VALVE