Manual Part No: 931762-01
MV1 Gas Steamer
- 9 –
Manual Rev No: 2
Installation (cont.)
Connection to Mains Services:
1)
Provide a rigid gas pipe no smaller than the size of steamer inlet connection, together with an
elbow or other suitable means of connection.
Note:
- Although rigid pipe is recommended,
armoured flexible pipe of a type approved for catering applications may be used.
2)
It is also recommended that an easily accessible stop valve be provided adjacent to the
appliance.
3)
Provide a rigid water supply pipe no smaller than the size of the inlet, together with an elbow or
other suitable means of connection.
Note:
- Although rigid pipe is recommended, a flexible hose
of a type approved for potable water may be used.
4)
It is recommended that an easily accessible stop tap be provided adjacent to the appliance.
5)
Connect steamer to gas & water supplies, ensuring that any dirt or swarf is removed.
It may be necessary to fit a Double Check Valve (
JE-DCV
) in the water supply in some areas to
meet Local Water Bylaws.
Note:
- Feed tank overflow maybe piped away by connecting a 1” Bore flexible pipe fastened
with a “Jubilee” type clip.